AZV7SA4810A*
AZV7SA · source records, page 3
62 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for AZV7SA4810A*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 62 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 16.2–17.5 | 62 / 62 |
| EER2 · BTU/Wh | 10 | 62 / 62 |
| HSPF2 · BTU/Wh | 8.5–8.8 | 62 / 62 |
| Cooling capacity · BTU/h | 45,500–46,500 | 62 / 62 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 46,000–47,500 | 62 / 62 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 28,400–29,000 | 62 / 62 |
| Heating capacity at 5°F / −15°C · BTU/h | 33,600 | 62 / 62 |
| COP at 5°F / −15°C | 2 | 62 / 62 |
| Equipment / loop type | HP - Split System | 62 / 62 |
| Refrigerant / source-reported GWP | R-32 (GWP:675 | Lower GWP) | 62 / 62 |
| Compressor staging | Continuously variable | 62 / 62 |
| Connected capability | No | 62 / 62 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Manufacturer specifications
These values match the manufacturer’s exact model pattern AZV7SA4810A*. They describe the unit, separately from the EPA system ratings. For electrical work, the specification sheet requires checking the installed unit’s rating plate and its full instructions.
| Specification | Value | Manufacturer evidence |
|---|---|---|
| Equipment weight | 179 lb | AZV7S S-SERIES — product specifications · page 3 ↗ |
| Maximum overcurrent protection | 40 A | AZV7S S-SERIES — product specifications · page 3 ↗ |
| Minimum circuit ampacity | 37.5 A | AZV7S S-SERIES — product specifications · page 3 ↗ |
| Shipping weight | 198 lb | AZV7S S-SERIES — product specifications · page 3 ↗ |
| Voltage / phase at 60 Hz | 208-230/1 V / phase | AZV7S S-SERIES — product specifications · page 3 ↗ |
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CHPEA4830*3A*+ furnace: A*VC961205DNB*Cold climate designationAHRI reference: 215487761 | 16.50 | 8.50 | 33600 | 2.00 | EPA 3628045 → |
CA*EA6030*3A*+ furnace: A*VS960805CUA*Cold climate designationAHRI reference: 215434391 | 16.20 | 8.80 | 33600 | 2.00 | EPA 3625319 → |
CA*EA6030*3A*+ furnace: A*VT960804CNA*Cold climate designationAHRI reference: 215434392 | 16.20 | 8.80 | 33600 | 2.00 | EPA 3625320 → |
CA*EA6030*3A*+ furnace: A*VT961005CNA*Cold climate designationAHRI reference: 215434393 | 16.20 | 8.80 | 33600 | 2.00 | EPA 3625321 → |
CA*EA6030*3A*+ furnace: A*VM970804CNA*Cold climate designationAHRI reference: 215434394 | 16.20 | 8.80 | 33600 | 2.00 | EPA 3625322 → |
CA*EA6030*3A*+ furnace: A*VM971005CNA*Cold climate designationAHRI reference: 215434395 | 16.20 | 8.80 | 33600 | 2.00 | EPA 3625323 → |
CHPEA4830*3A*+ furnace: A*VS960805CUA*Cold climate designationAHRI reference: 215434404 | 16.20 | 8.50 | 33600 | 2.00 | EPA 3625332 → |
CHPEA4830*3A*+ furnace: A*VT961005CNA*Cold climate designationAHRI reference: 215434406 | 16.20 | 8.50 | 33600 | 2.00 | EPA 3625333 → |
CHPEA4830*3A*+ furnace: A*VT960804CNA*Cold climate designationAHRI reference: 215434405 | 16.20 | 8.50 | 33600 | 2.00 | EPA 3625334 → |
CHPEA4830*3A*+ furnace: A*VM970804CNA*Cold climate designationAHRI reference: 215434407 | 16.20 | 8.50 | 33600 | 2.00 | EPA 3625335 → |
CHPEA4830*3A*+ furnace: A*VM971005CNA*Cold climate designationAHRI reference: 215434408 | 16.20 | 8.50 | 33600 | 2.00 | EPA 3625336 → |
CHPEA6030*3A*+ furnace: A*VS960805CUA*Cold climate designationAHRI reference: 215434417 | 16.20 | 8.50 | 33600 | 2.00 | EPA 3625345 → |
CHPEA6030*3A*+ furnace: A*VT960804CNA*Cold climate designationAHRI reference: 215434418 | 16.20 | 8.50 | 33600 | 2.00 | EPA 3625346 → |
CHPEA6030*3A*+ furnace: A*VT961005CNA*Cold climate designationAHRI reference: 215434419 | 16.20 | 8.50 | 33600 | 2.00 | EPA 3625347 → |
CHPEA6030*3A*+ furnace: A*VM970804CNA*Cold climate designationAHRI reference: 215434420 | 16.20 | 8.50 | 33600 | 2.00 | EPA 3625348 → |
CHPEA6030*3A*+ furnace: A*VM971005CNA*Cold climate designationAHRI reference: 215434421 | 16.20 | 8.50 | 33600 | 2.00 | EPA 3625349 → |
CA*EA6030*3A*+ furnace: A*VC960804CNB*Cold climate designationAHRI reference: 215487746 | 16.20 | 8.80 | 33600 | 2.00 | EPA 3628030 → |
CA*EA6030*3A*+ furnace: A*VC961005CNB*Cold climate designationAHRI reference: 215487747 | 16.20 | 8.80 | 33600 | 2.00 | EPA 3628031 → |
CHPEA4830*3A*+ furnace: A*VC960804CNB*Cold climate designationAHRI reference: 215487756 | 16.20 | 8.50 | 33600 | 2.00 | EPA 3628040 → |
CHPEA4830*3A*+ furnace: A*VC961005CNB*Cold climate designationAHRI reference: 215487757 | 16.20 | 8.50 | 33600 | 2.00 | EPA 3628041 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
AZV7S S-SERIES — product specifications ↗ — Manufacturer family specification sheet; only explicitly matched model patterns receive extracted values
Collection method, revision history and known limitations →