AC PRO / AIR-SOURCE HEAT PUMP

BH714S24P-**A

BH714S SERIES · BH714S Series · source records, page 3

90 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.2BTU/Wh
Cooling capacity22,800–24,000BTU/h

Each efficiency range summarizes published EPA records for BH714S24P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 90 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–1690 / 90
EER2 · BTU/Wh12–13.890 / 90
HSPF2 · BTU/Wh7.8–8.290 / 90
Cooling capacity · BTU/h22,800–24,00090 / 90
Heating capacity at 47°F / 8.3°C · BTU/h20,400–23,00090 / 90
Heating capacity at 17°F / −8.3°C · BTU/h12,900–14,70090 / 90
Heating capacity at 5°F / −15°C · BTU/h10,500–11,60090 / 90
COP at 5°F / −15°C1.96–2.1890 / 90
Equipment / loop typeHP - Split System90 / 90
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)90 / 90
Compressor stagingSingle stage90 / 90
Connected capabilityNo90 / 90

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
BC730HAT-**+TDR+ furnace: B80UR451E3AAHRI reference: 21637088515.207.80109002.02EPA 3813117 →
BC730HAT-**+TDR+ furnace: B80UR701E3AAHRI reference: 21637088615.208.00110002.04EPA 3813118 →
BC730HAT-**+TDR+ furnace: B80UR402V3AXAHRI reference: 21637088715.208.00111002.04EPA 3813119 →
BC730HBT-**+TDR+ furnace: B80UR801E4BXAHRI reference: 21637088815.208.00111002.06EPA 3813120 →
BC730HBT-**+TDR+ furnace: B95UR601E3BXAHRI reference: 21637089015.208.00112002.04EPA 3813121 →
BAH7E24PT-**AHRI reference: 21637081115.207.80110002.06EPA 3813138 →
BC724HAT-**+TDR+ furnace: B80UR701E3AAHRI reference: 21637086415.207.80107001.98EPA 3813140 →
BC724HAT-**+TDR+ furnace: B80UR402V3AXAHRI reference: 21637086515.207.80107001.96EPA 3813141 →
BC724HBT-**+TDR+ furnace: B80UR801E4BXAHRI reference: 21637086615.208.00108001.98EPA 3813142 →
BC724[C,U]AT-**+TDR+ furnace: B80UR401E3AXAHRI reference: 21637081615.207.80110002.02EPA 3813144 →
BC724[C,U]AT-**+TDR+ furnace: B80UR601E3AXAHRI reference: 21637081715.207.80110002.02EPA 3813145 →
BC724[C,U]AT-**+TDR+ furnace: B80UR702E3AAHRI reference: 21637081815.207.80110002.02EPA 3813146 →
BC730/36DBT-**+TDR+ furnace: B80DR902E4BAHRI reference: 21637091215.208.20114002.10EPA 3813170 →
BC730/36DBT-**+TDR+ furnace: B80DR901E4BAHRI reference: 21637091315.208.20113002.10EPA 3813171 →
BC730/36DCT-**+TDR+ furnace: B97DR902E4CAHRI reference: 21637091415.208.20113002.10EPA 3813172 →
BC730/36DCT-**+TDR+ furnace: B92DR901E4CAHRI reference: 21637091515.208.20114002.12EPA 3813173 →
BC730/36DCT-**+TDR+ furnace: B96DR901E4CAHRI reference: 21637091615.208.20113002.12EPA 3813174 →
BC724[C,U]BT-**+TDR+ furnace: B80UR902E3BAHRI reference: 21637082515.207.80110002.02EPA 3813186 →
BC724[C,U]BT-**+TDR+ furnace: B92UR451E3BAHRI reference: 21637083115.207.80110002.02EPA 3813190 →
BC724[C,U]BT-**+TDR+ furnace: B92UR701E3BAHRI reference: 21637083215.207.80110002.04EPA 3813191 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →