AC PRO / AIR-SOURCE HEAT PUMP

BH714S24P-**A

BH714S SERIES · BH714S Series · source records, page 2

90 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.2BTU/Wh
Cooling capacity22,800–24,000BTU/h

Each efficiency range summarizes published EPA records for BH714S24P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 90 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–1690 / 90
EER2 · BTU/Wh12–13.890 / 90
HSPF2 · BTU/Wh7.8–8.290 / 90
Cooling capacity · BTU/h22,800–24,00090 / 90
Heating capacity at 47°F / 8.3°C · BTU/h20,400–23,00090 / 90
Heating capacity at 17°F / −8.3°C · BTU/h12,900–14,70090 / 90
Heating capacity at 5°F / −15°C · BTU/h10,500–11,60090 / 90
COP at 5°F / −15°C1.96–2.1890 / 90
Equipment / loop typeHP - Split System90 / 90
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)90 / 90
Compressor stagingSingle stage90 / 90
Connected capabilityNo90 / 90

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
BC724HBT-**+TDR+ furnace: B80UR901E4BAHRI reference: 21637087415.508.10107002.02EPA 3813209
BC730HBT-**+TDR+ furnace: B97UR602V3BXAHRI reference: 21637090315.507.80109002.04EPA 3813232
BC730[C,U]AT-**+TDR+ furnace: B80UR451E3AAHRI reference: 21637084115.507.80112002.14EPA 3813796
BC724[C,U]AT-**+TDR+ furnace: B80UR402V3AXAHRI reference: 21637082115.507.80108002.02EPA 3813820
BC724[C,U]BT-**+TDR+ furnace: B97UR452V3BAHRI reference: 21649884615.507.80108002.02EPA 3847449
BC730[C,U]BT-**+TDR+ furnace: B97UR452V3BAHRI reference: 21649884715.508.00113002.14EPA 3847450
BC730HBT-**+TDR+ furnace: B97UR452V3BAHRI reference: 21649884915.507.80109002.06EPA 3847452
BC730[C,U]AT-**+TDR+ furnace: B80UR702V3AAHRI reference: 21680157315.508.00114002.14EPA 3993109
BC730[C,U]BT-**+TDR+ furnace: B97UR702V3BAHRI reference: 21680157515.508.00113002.16EPA 3993111
BC724HBT-**+TDR+ furnace: B97UR702V3BAHRI reference: 21680157915.508.10106002.00EPA 3993115
BC724CBT-**+TDR+ furnace: A98USMV070B12S*AHRI reference: 21696882315.507.80108002.02EPA 3996623
BC730CBT-**+TDR+ furnace: A98USMV070B12S*AHRI reference: 21696882515.508.00113002.14EPA 3996625
BC730HBT-**+TDR+ furnace: A98USMV070B12S*AHRI reference: 21696882615.507.80109002.06EPA 3996626
BC730[C,U]AT-**+TDR+ furnace: B80UR601E3AXAHRI reference: 21637083915.208.00115002.14EPA 3813089
BC730[C,U]BT-**+TDR+ furnace: B80UR801E4BXAHRI reference: 21637084415.208.00115002.12EPA 3813092
BC724HBT-**+TDR+ furnace: B96UR701E4BAHRI reference: 21637087815.208.10108002.00EPA 3813097
BC730HAT-**+TDR+ furnace: B80UR702E3AAHRI reference: 21637088415.208.00113002.04EPA 3813098
BC730HBT-**+TDR+ furnace: B97UR452E3BAHRI reference: 21637089315.207.80112002.04EPA 3813103
BC730HBT-**+TDR+ furnace: B97UR702E3BAHRI reference: 21637089415.207.80112002.04EPA 3813104
BC730HBT-**+TDR+ furnace: B92UR451E3BAHRI reference: 21637089715.208.00112002.06EPA 3813107