AC PRO / AIR-SOURCE HEAT PUMP

BH714S24P-**A

BH714S SERIES · BH714S Series · source records, page 4

90 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.2BTU/Wh
Cooling capacity22,800–24,000BTU/h

Each efficiency range summarizes published EPA records for BH714S24P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 90 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–1690 / 90
EER2 · BTU/Wh12–13.890 / 90
HSPF2 · BTU/Wh7.8–8.290 / 90
Cooling capacity · BTU/h22,800–24,00090 / 90
Heating capacity at 47°F / 8.3°C · BTU/h20,400–23,00090 / 90
Heating capacity at 17°F / −8.3°C · BTU/h12,900–14,70090 / 90
Heating capacity at 5°F / −15°C · BTU/h10,500–11,60090 / 90
COP at 5°F / −15°C1.96–2.1890 / 90
Equipment / loop typeHP - Split System90 / 90
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)90 / 90
Compressor stagingSingle stage90 / 90
Connected capabilityNo90 / 90

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
BC724[C,U]BT-**+TDR+ furnace: B96UR701E4BAHRI reference: 21637083415.207.80110002.04EPA 3813192
BC724[C,U]BT-**+TDR+ furnace: B80UR602V3AXAHRI reference: 21637083515.207.80109002.00EPA 3813193
BC724HBT-**+TDR+ furnace: B80UR902E3BAHRI reference: 21637086915.207.80105001.98EPA 3813206
BC724HBT-**+TDR+ furnace: B92UR701E3BAHRI reference: 21637087615.208.10108002.00EPA 3813210
BC730[C,U]BT-**+TDR+ furnace: B92UR451E3BAHRI reference: 21637085315.208.00116002.14EPA 3813217
BC730[C,U]BT-**+TDR+ furnace: B92UR701E3BAHRI reference: 21637085415.208.10115002.14EPA 3813218
BC730[C,U]BT-**+TDR+ furnace: B96UR701E4BAHRI reference: 21637085615.208.10115002.14EPA 3813220
BC730[C,U]BT-**+TDR+ furnace: B97UR402V3BXAHRI reference: 21637085815.207.80115002.12EPA 3813221
BC730[C,U]BT-**+TDR+ furnace: B97UR602V3BXAHRI reference: 21637085915.208.00113002.12EPA 3813222
BC730[C,U]BT-**+TDR+ furnace: B80UR602V3AXAHRI reference: 21637085715.207.80114002.12EPA 3813223
BC730HBT-**+TDR+ furnace: B80UR602V3AXAHRI reference: 21637090115.207.80110002.04EPA 3813230
BC730HBT-**+TDR+ furnace: B97UR402V3BXAHRI reference: 21637090215.207.80110002.04EPA 3813231
BC730HBT-**+TDR+ furnace: B95UR401E3BXAHRI reference: 21637088915.207.80112002.04EPA 3813787
BC724[C,U]BT-**+TDR+ furnace: B97UR602V3BXAHRI reference: 21637083715.207.80108002.02EPA 3813793
BC730[C,U]AT-**+TDR+ furnace: B80UR401E3AXAHRI reference: 21637083815.208.00115002.14EPA 3813794
BC730[C,U]AT-**+TDR+ furnace: B80UR702E3AAHRI reference: 21637084015.208.00116002.14EPA 3813795
BC730HAT-**+TDR+ furnace: B80UR401E3AXAHRI reference: 21637088215.208.00112002.02EPA 3813798
BC730HAT-**+TDR+ furnace: B80UR601E3AXAHRI reference: 21637088315.208.00112002.02EPA 3813799
BC724HBT-**+TDR+ furnace: B97UR452V3BAHRI reference: 21649884815.208.00106001.98EPA 3847451
BC724[C,U]BT-**+TDR+ furnace: B80UR902V4BAHRI reference: 21680157115.207.80108002.00EPA 3993108