YH648E2S11
LX SERIES · source records, page 9
554 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for YH648E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 554 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 554 / 554 |
| EER2 · BTU/Wh | 11.7–12 | 554 / 554 |
| HSPF2 · BTU/Wh | 7.8–8.1 | 554 / 554 |
| Cooling capacity · BTU/h | 45,000–49,000 | 554 / 554 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 46,000–50,000 | 554 / 554 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 31,800–34,000 | 554 / 554 |
| Heating capacity at 5°F / −15°C · BTU/h | 25,000–27,800 | 554 / 554 |
| COP at 5°F / −15°C | 2–2.4 | 554 / 554 |
| Equipment / loop type | HP - Split System | 554 / 554 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 554 / 554 |
| Compressor staging | Two-stage | 554 / 554 |
| Connected capability | No | 554 / 554 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTM60C5CGS1+ furnace: Y92E100C20SMPS1AHRI reference: 217021916 | 16.00 | 8.10 | 27400 | 2.22 | EPA 4015217 → |
CTM60C5CGS1+ furnace: Y82E120C20LMPS1AHRI reference: 217021936 | 16.00 | 8.10 | 27600 | 2.26 | EPA 4015219 → |
CTM60D5CGS1+ furnace: Y81E130D20SMPS1AHRI reference: 217021901 | 16.00 | 8.10 | 27400 | 2.28 | EPA 4015255 → |
CTM60C5CGS1+ furnace: Y92E080C16SMPS1AHRI reference: 217021904 | 16.00 | 8.10 | 27200 | 2.22 | EPA 4015256 → |
CTM60C5CGS1+ furnace: Y81E120C20SMPS1AHRI reference: 217021905 | 16.00 | 8.10 | 27200 | 2.26 | EPA 4015257 → |
CTM60C5CGS1+ furnace: Y81E120C20LMPS1AHRI reference: 217021906 | 16.00 | 8.10 | 27200 | 2.26 | EPA 4015258 → |
CTM60C5CGS1+JMET16CS2N1AHRI reference: 217021907 | 16.00 | 8.10 | 27400 | 2.26 | EPA 4015259 → |
CTM60C5CGS1+JMC17C2SN1AHRI reference: 217021908 | 16.00 | 8.10 | 27000 | 2.28 | EPA 4015260 → |
CTM60C5CGS1+ furnace: Y81E080C20LMPS1AHRI reference: 217021910 | 16.00 | 8.10 | 27200 | 2.26 | EPA 4015261 → |
CTM60C5CGS1+ furnace: Y81E080C20SMPS1AHRI reference: 217021909 | 16.00 | 8.10 | 27200 | 2.26 | EPA 4015262 → |
CTM60C5CGS1+ furnace: Y92E100C16SMPS1AHRI reference: 217021911 | 16.00 | 8.10 | 27400 | 2.22 | EPA 4015263 → |
CTM60C5CGS1+ furnace: Y91E080C16SMPS1AHRI reference: 217021912 | 16.00 | 8.10 | 27200 | 2.22 | EPA 4015264 → |
CTM60C5CGS1+ furnace: Y82E100C16LMPS1AHRI reference: 217021913 | 16.00 | 8.10 | 27000 | 2.26 | EPA 4015265 → |
CTM60C5CGS1+JMET12CS2N1AHRI reference: 217021914 | 16.00 | 8.10 | 26800 | 2.26 | EPA 4015266 → |
CTM60C5CGS1+JMVT17CC2N1AHRI reference: 217021915 | 16.00 | 8.10 | 27000 | 2.28 | EPA 4015267 → |
CTM60D5CGS1+JMET18DS2N1AHRI reference: 217021917 | 16.00 | 8.10 | 27200 | 2.28 | EPA 4015268 → |
CTM60C5CGS1+ furnace: Y81E080C16LMPS1AHRI reference: 217021919 | 16.00 | 8.10 | 26800 | 2.26 | EPA 4015270 → |
CTM60C5CGS1+ furnace: Y81E080C16SMPS1AHRI reference: 217021918 | 16.00 | 8.10 | 26800 | 2.26 | EPA 4015271 → |
JHC48D5CG2SS1AHRI reference: 217021921 | 16.00 | 8.10 | 27200 | 2.28 | EPA 4015273 → |
CTM60C5CGS1+ furnace: Y82E100C20LMPS1AHRI reference: 217021922 | 16.00 | 8.10 | 27600 | 2.26 | EPA 4015274 → |