YH648E2S11
LX SERIES · source records, page 8
554 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for YH648E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 554 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 554 / 554 |
| EER2 · BTU/Wh | 11.7–12 | 554 / 554 |
| HSPF2 · BTU/Wh | 7.8–8.1 | 554 / 554 |
| Cooling capacity · BTU/h | 45,000–49,000 | 554 / 554 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 46,000–50,000 | 554 / 554 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 31,800–34,000 | 554 / 554 |
| Heating capacity at 5°F / −15°C · BTU/h | 25,000–27,800 | 554 / 554 |
| COP at 5°F / −15°C | 2–2.4 | 554 / 554 |
| Equipment / loop type | HP - Split System | 554 / 554 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 554 / 554 |
| Compressor staging | Two-stage | 554 / 554 |
| Connected capability | No | 554 / 554 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTF60D5CGS1+ furnace: Y81E130D20SMPS1AHRI reference: 217019428 | 16.00 | 8.10 | 27400 | 2.28 | EPA 4014615 → |
CTF60D5CGS1+ furnace: Y81E130D20LMPS1AHRI reference: 217019430 | 16.00 | 8.10 | 27400 | 2.28 | EPA 4014616 → |
CTU60D5XGS1+TXV+ furnace: Y81E130D20SMPS1AHRI reference: 217019432 | 16.00 | 8.10 | 27400 | 2.28 | EPA 4014618 → |
CTU60D5XGS1+TXV+ furnace: Y81E130D20LMPS1AHRI reference: 217019434 | 16.00 | 8.10 | 27400 | 2.28 | EPA 4014619 → |
CTF60C5CHS1+JMET16CS2N1AHRI reference: 217019436 | 16.00 | 8.10 | 27000 | 2.34 | EPA 4014622 → |
CTF60D5CHS1+JMVT20DC2N1AHRI reference: 217019438 | 16.00 | 8.10 | 27000 | 2.38 | EPA 4014623 → |
CTF60C5CHS1+JMC17C2SN1AHRI reference: 217019442 | 16.00 | 8.10 | 27000 | 2.36 | EPA 4014625 → |
CTU60D5XHS1+JMVT20DC2N1+TXVAHRI reference: 217019440 | 16.00 | 8.10 | 27000 | 2.38 | EPA 4014626 → |
CTF60C5CHS1+ furnace: Y81E080C20SMPS1AHRI reference: 217019444 | 16.00 | 8.10 | 27400 | 2.34 | EPA 4014627 → |
CTF60C5CHS1+ furnace: Y81E080C20LMPS1AHRI reference: 217019446 | 16.00 | 8.10 | 27400 | 2.34 | EPA 4014628 → |
CTF60C5CHS1+ furnace: Y91E100C20SMPS1AHRI reference: 217019448 | 16.00 | 8.10 | 27400 | 2.30 | EPA 4014630 → |
CTM60C5CHS1+ furnace: Y92E100C20SMPS1AHRI reference: 217019462 | 16.00 | 8.10 | 27000 | 2.32 | EPA 4014680 → |
CTM60C5CHS1+ furnace: Y81E080C20SMPS1AHRI reference: 217019450 | 16.00 | 8.10 | 26800 | 2.34 | EPA 4014740 → |
CTM60C5CHS1+ furnace: Y81E080C20LMPS1AHRI reference: 217019452 | 16.00 | 8.10 | 26800 | 2.34 | EPA 4014741 → |
JHE60C5CH2SS1AHRI reference: 217019454 | 16.00 | 8.10 | 27200 | 2.34 | EPA 4014742 → |
CTM60C5CHS1+JMC17C2SN1AHRI reference: 217019458 | 16.00 | 8.10 | 26600 | 2.36 | EPA 4014743 → |
CTM60C5CHS1+JMVT16CC2N1AHRI reference: 217019460 | 16.00 | 8.10 | 27000 | 2.36 | EPA 4014744 → |
CTM60D5CHS1+ furnace: Y81E130D20SMPS1AHRI reference: 217019464 | 16.00 | 8.10 | 27000 | 2.36 | EPA 4014745 → |
CTM60D5CHS1+ furnace: Y81E130D20LMPS1AHRI reference: 217019466 | 16.00 | 8.10 | 27000 | 2.36 | EPA 4014747 → |
CTM60D5CGS1+ furnace: Y81E130D20LMPS1AHRI reference: 217021902 | 16.00 | 8.10 | 27400 | 2.28 | EPA 4015207 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.