York / AIR-SOURCE HEAT PUMP

YH648E2S11

LX SERIES · source records, page 3

554 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity45,000–49,000BTU/h

Each efficiency range summarizes published EPA records for YH648E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 554 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16554 / 554
EER2 · BTU/Wh11.7–12554 / 554
HSPF2 · BTU/Wh7.8–8.1554 / 554
Cooling capacity · BTU/h45,000–49,000554 / 554
Heating capacity at 47°F / 8.3°C · BTU/h46,000–50,000554 / 554
Heating capacity at 17°F / −8.3°C · BTU/h31,800–34,000554 / 554
Heating capacity at 5°F / −15°C · BTU/h25,000–27,800554 / 554
COP at 5°F / −15°C2–2.4554 / 554
Equipment / loop typeHP - Split System554 / 554
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)554 / 554
Compressor stagingTwo-stage554 / 554
Connected capabilityNo554 / 554

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTM60D5CHS1+JME18D2SN1AHRI reference: 21701929216.008.10268002.38EPA 4014213 →
CTF60C5CGS1+ furnace: Y81E120C20SMPS1AHRI reference: 21701929616.008.10272002.24EPA 4014216 →
CTF60C5CGS1+ furnace: Y81E120C20LMPS1AHRI reference: 21701929816.008.10272002.24EPA 4014218 →
CTU60C5XGS1+TXV+ furnace: Y81E120C20SMPS1AHRI reference: 21701930016.008.10272002.24EPA 4014220 →
CTU60C5XGS1+TXV+ furnace: Y81E120C20LMPS1AHRI reference: 21701930216.008.10272002.24EPA 4014222 →
CTF60C5CGS1+JMET16CS2N1AHRI reference: 21701930416.008.10274002.26EPA 4014224 →
CTU60C5XGS1+JMET16CS2N1+TXVAHRI reference: 21701930616.008.10274002.26EPA 4014226 →
CTF60C5CGS1+JMET12CS2N1AHRI reference: 21701930816.008.10268002.26EPA 4014228 →
CTU60C5XGS1+JMET12CS2N1+TXVAHRI reference: 21701931116.008.10268002.26EPA 4014231 →
CTF60D5CGS1+JME18D2SN1AHRI reference: 21701931316.008.10270002.30EPA 4014233 →
CTU60D5XGS1+JME18D2SN1+TXVAHRI reference: 21701931516.008.10270002.30EPA 4014235 →
CTF60C5CGS1+ furnace: Y82E100C20LMPS1AHRI reference: 21701932116.008.10276002.26EPA 4014239 →
CTU60C5XGS1+TXV+ furnace: Y82E100C20LMPS1AHRI reference: 21701932316.008.10276002.26EPA 4014241 →
CTF60C5CHS1+JMET12CS2N1AHRI reference: 21701932516.008.10264002.34EPA 4014243 →
CTF60C5CHS1+JME12C2SN1AHRI reference: 21701932716.008.10264002.36EPA 4014245 →
CTF60C5CHS1+JME16C2SN1AHRI reference: 21701932916.008.10268002.36EPA 4014247 →
CTF60C5CHS1+ furnace: Y91E080C20SMPS1AHRI reference: 21701933116.008.10276002.30EPA 4014249 →
CTF60C5CHS1+ furnace: Y81E080C16SMPS1AHRI reference: 21701933516.008.10268002.34EPA 4014252 →
CTF60C5CHS1+ furnace: Y81E080C16LMPS1AHRI reference: 21701933716.008.10268002.34EPA 4014254 →
CTM60C5CHS1+ furnace: Y82E100C16LMPS1AHRI reference: 21701933916.008.10272002.32EPA 4014256 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →