YH648E2S11
LX SERIES · source records, page 2
554 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for YH648E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 554 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 554 / 554 |
| EER2 · BTU/Wh | 11.7–12 | 554 / 554 |
| HSPF2 · BTU/Wh | 7.8–8.1 | 554 / 554 |
| Cooling capacity · BTU/h | 45,000–49,000 | 554 / 554 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 46,000–50,000 | 554 / 554 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 31,800–34,000 | 554 / 554 |
| Heating capacity at 5°F / −15°C · BTU/h | 25,000–27,800 | 554 / 554 |
| COP at 5°F / −15°C | 2–2.4 | 554 / 554 |
| Equipment / loop type | HP - Split System | 554 / 554 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 554 / 554 |
| Compressor staging | Two-stage | 554 / 554 |
| Connected capability | No | 554 / 554 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTF60C5CGS1+ furnace: Y81E100C20LMPS1AHRI reference: 217019188 | 16.00 | 8.10 | 27200 | 2.26 | EPA 4014153 → |
CTU60C5XGS1+TXV+ furnace: Y81E100C20SMPS1AHRI reference: 217019190 | 16.00 | 8.10 | 27200 | 2.26 | EPA 4014156 → |
CTU60C5XGS1+TXV+ furnace: Y81E100C20LMPS1AHRI reference: 217019192 | 16.00 | 8.10 | 27200 | 2.26 | EPA 4014158 → |
CTF60C5CGS1+ furnace: Y92E100C20SMPS1AHRI reference: 217019194 | 16.00 | 8.10 | 27400 | 2.22 | EPA 4014160 → |
CTU60C5XGS1+TXV+ furnace: Y92E100C20SMPS1AHRI reference: 217019196 | 16.00 | 8.10 | 27400 | 2.22 | EPA 4014162 → |
CTF60C5CGS1+ furnace: Y82E120C20LMPS1AHRI reference: 217019198 | 16.00 | 8.10 | 27600 | 2.26 | EPA 4014165 → |
CTU60C5XGS1+TXV+ furnace: Y82E120C20LMPS1AHRI reference: 217019200 | 16.00 | 8.10 | 27600 | 2.26 | EPA 4014167 → |
CTF60C5CHS1+ furnace: Y81E120C20SMPS1AHRI reference: 217019202 | 16.00 | 8.10 | 27400 | 2.32 | EPA 4014169 → |
CTF60C5CHS1+ furnace: Y81E120C20LMPS1AHRI reference: 217019204 | 16.00 | 8.10 | 27400 | 2.32 | EPA 4014171 → |
CTF60C5CHS1+ furnace: Y82E100C20LMPS1AHRI reference: 217019206 | 16.00 | 8.10 | 27400 | 2.32 | EPA 4014173 → |
CTF60D5CHS1+ furnace: Y81E130D20SMPS1AHRI reference: 217019208 | 16.00 | 8.10 | 27000 | 2.36 | EPA 4014175 → |
CTF60D5CHS1+ furnace: Y81E130D20LMPS1AHRI reference: 217019210 | 16.00 | 8.10 | 27000 | 2.36 | EPA 4014177 → |
JHE48C5CG2SS1AHRI reference: 217016558 | 16.00 | 8.00 | 27200 | 2.10 | EPA 4014179 → |
CTF60D5CHS1+ furnace: Y91E120D20SMPS1AHRI reference: 217019278 | 16.00 | 8.10 | 27200 | 2.32 | EPA 4014198 → |
CTU60D5XHS1+TXV+ furnace: Y91E120D20SMPS1AHRI reference: 217019280 | 16.00 | 8.10 | 27200 | 2.32 | EPA 4014201 → |
JHE60D5CH2SS1AHRI reference: 217019284 | 16.00 | 8.10 | 27000 | 2.38 | EPA 4014204 → |
CTM60C5CHS1+ furnace: Y81E120C20SMPS1AHRI reference: 217019286 | 16.00 | 8.10 | 27400 | 2.32 | EPA 4014206 → |
CTM60C5CHS1+ furnace: Y81E120C20LMPS1AHRI reference: 217019288 | 16.00 | 8.10 | 27400 | 2.32 | EPA 4014208 → |
CTM60D5CHS1+ furnace: Y91E120D20SMPS1AHRI reference: 217019290 | 16.00 | 8.10 | 27600 | 2.30 | EPA 4014211 → |
CTM60C5CHS1+ furnace: Y91E100C20SMPS1AHRI reference: 217019294 | 16.00 | 8.10 | 27800 | 2.28 | EPA 4014212 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →