166 published source records · source checked Sep 21, 2026

SEER2 range15.2–17BTU/Wh
HSPF2 range8–8.1BTU/Wh
Cooling capacity28,400–31,000BTU/h

Each efficiency range summarizes published EPA records for YH630E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 166 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17166 / 166
EER2 · BTU/Wh11–13166 / 166
HSPF2 · BTU/Wh8–8.1166 / 166
Cooling capacity · BTU/h28,400–31,000166 / 166
Heating capacity at 47°F / 8.3°C · BTU/h28,800–30,000166 / 166
Heating capacity at 17°F / −8.3°C · BTU/h18,800–20,200166 / 166
Heating capacity at 5°F / −15°C · BTU/h15,000–16,400166 / 166
COP at 5°F / −15°C2–2.4166 / 166
Equipment / loop typeHP - Split System166 / 166
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)166 / 166
Compressor stagingTwo-stage166 / 166
Connected capabilityNo166 / 166

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTM30B5AZS2+ furnace: Y92E060B12SMPS1AHRI reference: 21868703915.208.10160002.00EPA 4673414
CTM30B5AZS2+ furnace: TM9E060B12MP12AHRI reference: 21868703715.208.10156002.00EPA 4673416
CTM30B5AZS2+ furnace: YP9C080B12MP13AHRI reference: 21868703615.208.10156002.00EPA 4673417
CTM30B5AZS2+ furnace: TP9C080B12MP13AHRI reference: 21868703515.208.10156002.00EPA 4673418
CTM30B5AZS2+ furnace: TM9V080B12MP12AHRI reference: 21868703415.208.10156002.00EPA 4673419
CTF30B5AZS2+ furnace: TM9E080B12MP12AHRI reference: 21868703315.208.10154002.00EPA 4673420

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →