YH630E2S11
LX SERIES · source records, page 8
166 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for YH630E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 166 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–17 | 166 / 166 |
| EER2 · BTU/Wh | 11–13 | 166 / 166 |
| HSPF2 · BTU/Wh | 8–8.1 | 166 / 166 |
| Cooling capacity · BTU/h | 28,400–31,000 | 166 / 166 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 28,800–30,000 | 166 / 166 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 18,800–20,200 | 166 / 166 |
| Heating capacity at 5°F / −15°C · BTU/h | 15,000–16,400 | 166 / 166 |
| COP at 5°F / −15°C | 2–2.4 | 166 / 166 |
| Equipment / loop type | HP - Split System | 166 / 166 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 166 / 166 |
| Compressor staging | Two-stage | 166 / 166 |
| Connected capability | No | 166 / 166 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTM30B5AZS2+ furnace: Y91E060B12SMPS1AHRI reference: 218687070 | 15.20 | 8.10 | 16400 | 2.00 | EPA 4673383 → |
CTM30B5AZS2+ furnace: TM9Y080B12MP11AHRI reference: 218687068 | 15.20 | 8.10 | 15800 | 2.00 | EPA 4673385 → |
CTF30B5AZS2+ furnace: YP9C080B12MP13AHRI reference: 218687066 | 15.20 | 8.10 | 15200 | 2.00 | EPA 4673387 → |
CTF30B5AZS2+ furnace: TP9C080B12MP13AHRI reference: 218687065 | 15.20 | 8.10 | 15200 | 2.00 | EPA 4673388 → |
CTF30B5AZS2+ furnace: TM9V080B12MP12AHRI reference: 218687064 | 15.20 | 8.10 | 15200 | 2.00 | EPA 4673389 → |
CTM30B5AZS2+ furnace: YPLC080B12MP13AHRI reference: 218687062 | 15.20 | 8.10 | 15600 | 2.00 | EPA 4673391 → |
CTM30B5AZS2+ furnace: TPLC080B12MP13AHRI reference: 218687061 | 15.20 | 8.10 | 15600 | 2.00 | EPA 4673392 → |
CTM30B5AZS2+ furnace: TM8V080B12MP12AHRI reference: 218687060 | 15.20 | 8.10 | 15600 | 2.00 | EPA 4673393 → |
CTF30B5AZS2+ furnace: Y91E060B12SMPS1AHRI reference: 218687056 | 15.20 | 8.10 | 16000 | 2.00 | EPA 4673397 → |
CTF30B5AZS2+ furnace: YPLC080B12MP13AHRI reference: 218687055 | 15.20 | 8.10 | 15400 | 2.00 | EPA 4673398 → |
CTF30B5AZS2+ furnace: TPLC080B12MP13AHRI reference: 218687054 | 15.20 | 8.10 | 15400 | 2.00 | EPA 4673399 → |
CTF30B5AZS2+ furnace: TM8V080B12MP12AHRI reference: 218687053 | 15.20 | 8.10 | 15400 | 2.00 | EPA 4673400 → |
CTF30B5AZS2+ furnace: YP9C060B12MP13AHRI reference: 218687052 | 15.20 | 8.10 | 15800 | 2.00 | EPA 4673401 → |
CTF30B5AZS2+ furnace: TP9C060B12MP13AHRI reference: 218687051 | 15.20 | 8.10 | 15800 | 2.00 | EPA 4673402 → |
CTF30B5AZS2+ furnace: TM9V060B12MP12AHRI reference: 218687050 | 15.20 | 8.10 | 15800 | 2.00 | EPA 4673403 → |
CTM30B5AZS2+ furnace: TM9E080B12MP12AHRI reference: 218687049 | 15.20 | 8.10 | 16000 | 2.00 | EPA 4673404 → |
CTM30B5AZS2+ furnace: YP9C060B12MP13AHRI reference: 218687045 | 15.20 | 8.10 | 15800 | 2.00 | EPA 4673408 → |
CTM30B5AZS2+ furnace: TP9C060B12MP13AHRI reference: 218687044 | 15.20 | 8.10 | 15800 | 2.00 | EPA 4673409 → |
CTM30B5AZS2+ furnace: TM9V060B12MP12AHRI reference: 218687043 | 15.20 | 8.10 | 15800 | 2.00 | EPA 4673410 → |
CTM30B5AZS2+ furnace: TM9Y060B12MP11AHRI reference: 218687041 | 15.20 | 8.10 | 15800 | 2.00 | EPA 4673412 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.