YH548E2S11
LX SERIES · source records, page 3
381 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for YH548E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 381 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 381 / 381 |
| EER2 · BTU/Wh | 11–12 | 381 / 381 |
| HSPF2 · BTU/Wh | 7.8–8.1 | 381 / 381 |
| Cooling capacity · BTU/h | 45,500–48,000 | 381 / 381 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 45,000–48,000 | 381 / 381 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 29,200–32,400 | 381 / 381 |
| Heating capacity at 5°F / −15°C · BTU/h | 24,600–27,200 | 381 / 381 |
| COP at 5°F / −15°C | 2.1–2.42 | 381 / 381 |
| Equipment / loop type | HP - Split System | 381 / 381 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 381 / 381 |
| Compressor staging | Two-stage | 381 / 381 |
| Connected capability | No | 381 / 381 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTF60C5CHS1+ furnace: Y82E120C20LMPS1AHRI reference: 215742774 | 15.20 | 7.80 | 26000 | 2.40 | EPA 3653143 → |
CTF60C5CHS1+ furnace: Y82E100C16LMPS1AHRI reference: 215742778 | 15.20 | 7.80 | 26000 | 2.40 | EPA 3653146 → |
CTM60C5CHS1+ furnace: Y82E100C16LMPS1AHRI reference: 216437613 | 15.20 | 8.00 | 26000 | 2.40 | EPA 3815007 → |
CTM60C5CHS1+ furnace: Y92E080C16SMPS1AHRI reference: 216437614 | 15.20 | 7.80 | 26200 | 2.34 | EPA 3815008 → |
CTM60C5CHS1+ furnace: Y82E080C16LMPS1AHRI reference: 216437615 | 15.20 | 8.00 | 26000 | 2.40 | EPA 3815009 → |
CTM60C5CHS1+ furnace: Y82E100C20LMPS1AHRI reference: 216437616 | 15.20 | 8.10 | 26200 | 2.40 | EPA 3815010 → |
CTM60C5CHS1+ furnace: Y82E120C20LMPS1AHRI reference: 216437617 | 15.20 | 8.00 | 26000 | 2.40 | EPA 3815011 → |
CTM60C5CHS1+ furnace: Y92E100C16SMPS1AHRI reference: 216437618 | 15.20 | 8.00 | 25800 | 2.38 | EPA 3815012 → |
CTM60C5CHS1+ furnace: Y92E100C20SMPS1AHRI reference: 216437619 | 15.20 | 8.00 | 26400 | 2.36 | EPA 3815013 → |
CTM60D5CHS1+ furnace: Y92E120D20SMPS1AHRI reference: 216437620 | 15.20 | 8.00 | 26600 | 2.36 | EPA 3815014 → |
CTM60C5CHS1+ furnace: Y81E120C16SMPS1AHRI reference: 214424784 | 15.20 | 8.10 | 26400 | 2.38 | EPA 3892798 → |
CTM60D5CHS1+JME18D2SN1AHRI reference: 214424781 | 15.20 | 8.10 | 26200 | 2.42 | EPA 3892799 → |
CTM60D5CHS1+JMET18DS2N1AHRI reference: 214424902 | 15.20 | 8.10 | 26200 | 2.42 | EPA 3892800 → |
CTM60C5CHS1+ furnace: Y81E100C16SMPS1AHRI reference: 214424852 | 15.20 | 8.10 | 26600 | 2.36 | EPA 3892801 → |
CTM60C5CHS1+JMET16CS2N1AHRI reference: 214424900 | 15.20 | 8.10 | 26400 | 2.40 | EPA 3892802 → |
CTM60D5CHS1+ furnace: Y81E130D20SMPS1AHRI reference: 214424854 | 15.20 | 8.10 | 26400 | 2.40 | EPA 3892803 → |
CTM60C5CHS1+ furnace: Y81E080C20SMPS1AHRI reference: 214425020 | 15.20 | 8.10 | 26200 | 2.40 | EPA 3892804 → |
JHC48C5CG2SS1AHRI reference: 214424914 | 15.20 | 7.80 | 24800 | 2.26 | EPA 3892805 → |
CTM60C5CHS1+ furnace: Y81E080C16SMPS1AHRI reference: 214425023 | 15.20 | 8.00 | 26000 | 2.40 | EPA 3892807 → |
CTM60D5CHS1+JMVT20DC2N1AHRI reference: 214425304 | 15.20 | 8.10 | 26200 | 2.42 | EPA 3892808 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →