York / AIR-SOURCE HEAT PUMP

YH548E2S11

LX SERIES · source records, page 3

381 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity45,500–48,000BTU/h

Each efficiency range summarizes published EPA records for YH548E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 381 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16381 / 381
EER2 · BTU/Wh11–12381 / 381
HSPF2 · BTU/Wh7.8–8.1381 / 381
Cooling capacity · BTU/h45,500–48,000381 / 381
Heating capacity at 47°F / 8.3°C · BTU/h45,000–48,000381 / 381
Heating capacity at 17°F / −8.3°C · BTU/h29,200–32,400381 / 381
Heating capacity at 5°F / −15°C · BTU/h24,600–27,200381 / 381
COP at 5°F / −15°C2.1–2.42381 / 381
Equipment / loop typeHP - Split System381 / 381
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)381 / 381
Compressor stagingTwo-stage381 / 381
Connected capabilityNo381 / 381

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTF60C5CHS1+ furnace: Y82E120C20LMPS1AHRI reference: 21574277415.207.80260002.40EPA 3653143
CTF60C5CHS1+ furnace: Y82E100C16LMPS1AHRI reference: 21574277815.207.80260002.40EPA 3653146
CTM60C5CHS1+ furnace: Y82E100C16LMPS1AHRI reference: 21643761315.208.00260002.40EPA 3815007
CTM60C5CHS1+ furnace: Y92E080C16SMPS1AHRI reference: 21643761415.207.80262002.34EPA 3815008
CTM60C5CHS1+ furnace: Y82E080C16LMPS1AHRI reference: 21643761515.208.00260002.40EPA 3815009
CTM60C5CHS1+ furnace: Y82E100C20LMPS1AHRI reference: 21643761615.208.10262002.40EPA 3815010
CTM60C5CHS1+ furnace: Y82E120C20LMPS1AHRI reference: 21643761715.208.00260002.40EPA 3815011
CTM60C5CHS1+ furnace: Y92E100C16SMPS1AHRI reference: 21643761815.208.00258002.38EPA 3815012
CTM60C5CHS1+ furnace: Y92E100C20SMPS1AHRI reference: 21643761915.208.00264002.36EPA 3815013
CTM60D5CHS1+ furnace: Y92E120D20SMPS1AHRI reference: 21643762015.208.00266002.36EPA 3815014
CTM60C5CHS1+ furnace: Y81E120C16SMPS1AHRI reference: 21442478415.208.10264002.38EPA 3892798
CTM60D5CHS1+JME18D2SN1AHRI reference: 21442478115.208.10262002.42EPA 3892799
CTM60D5CHS1+JMET18DS2N1AHRI reference: 21442490215.208.10262002.42EPA 3892800
CTM60C5CHS1+ furnace: Y81E100C16SMPS1AHRI reference: 21442485215.208.10266002.36EPA 3892801
CTM60C5CHS1+JMET16CS2N1AHRI reference: 21442490015.208.10264002.40EPA 3892802
CTM60D5CHS1+ furnace: Y81E130D20SMPS1AHRI reference: 21442485415.208.10264002.40EPA 3892803
CTM60C5CHS1+ furnace: Y81E080C20SMPS1AHRI reference: 21442502015.208.10262002.40EPA 3892804
JHC48C5CG2SS1AHRI reference: 21442491415.207.80248002.26EPA 3892805
CTM60C5CHS1+ furnace: Y81E080C16SMPS1AHRI reference: 21442502315.208.00260002.40EPA 3892807
CTM60D5CHS1+JMVT20DC2N1AHRI reference: 21442530415.208.10262002.42EPA 3892808

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →