York / AIR-SOURCE HEAT PUMP

YH548E2S11

LX SERIES · source records, page 2

381 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity45,500–48,000BTU/h

Each efficiency range summarizes published EPA records for YH548E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 381 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16381 / 381
EER2 · BTU/Wh11–12381 / 381
HSPF2 · BTU/Wh7.8–8.1381 / 381
Cooling capacity · BTU/h45,500–48,000381 / 381
Heating capacity at 47°F / 8.3°C · BTU/h45,000–48,000381 / 381
Heating capacity at 17°F / −8.3°C · BTU/h29,200–32,400381 / 381
Heating capacity at 5°F / −15°C · BTU/h24,600–27,200381 / 381
COP at 5°F / −15°C2.1–2.42381 / 381
Equipment / loop typeHP - Split System381 / 381
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)381 / 381
Compressor stagingTwo-stage381 / 381
Connected capabilityNo381 / 381

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTM60D5CHS1+ furnace: TM8E130D20MP11AHRI reference: 21442549515.207.80272002.32EPA 3557572
CTM60D5CHS1+ furnace: TMLE130D20MP11AHRI reference: 21442549715.207.80272002.32EPA 3557574
JHC60D5CH2SS1AHRI reference: 21442553215.208.10264002.42EPA 3557578
JHE60D5CH2SS1AHRI reference: 21442553415.208.10262002.42EPA 3557579
CTM60C5CHS1+ furnace: TM8E080C20MP11AHRI reference: 21442559515.207.80262002.36EPA 3557588
CTM60C5CHS1+ furnace: TMLE080C20MP11AHRI reference: 21442559715.207.80262002.36EPA 3557589
CTM60C5CHS1+ furnace: TM8Y100C16MP11AHRI reference: 21442560515.207.80258002.36EPA 3557590
CTM60C5CHS1+ furnace: TM8Y080C16MP11AHRI reference: 21442560715.207.80258002.36EPA 3557591
CTF60C5CHS1+ furnace: TM8Y100C16MP11AHRI reference: 21442570015.207.80258002.36EPA 3557592
CTF60C5CHS1+ furnace: TM8Y080C16MP11AHRI reference: 21442570215.207.80258002.36EPA 3557593
JHC48D5CG2SS1AHRI reference: 21442573615.207.80248002.26EPA 3557594
CTF60C5CHS1+ furnace: TM8E080C20MP11AHRI reference: 21442584515.207.80262002.36EPA 3557595
CTF60C5CHS1+ furnace: TMLE080C20MP11AHRI reference: 21442584715.207.80262002.36EPA 3557596
CTM60C5CHS1+ furnace: TM8Y120C20MP11AHRI reference: 21442590215.207.80262002.36EPA 3557597
CTM60C5CHS1+ furnace: TM8Y100C20MP11AHRI reference: 21442590415.207.80262002.36EPA 3557598
JHC60C5CH2SS1AHRI reference: 21442597915.208.10266002.38EPA 3557599
JSC48D5CG2SS1AHRI reference: 21483352915.207.80248002.26EPA 3557755
JSE48D5CG2SS1AHRI reference: 21483353015.207.80246002.26EPA 3557756
JHE48C5CG2SS1AHRI reference: 21442469815.207.80248002.10EPA 3627809
CTF60C5CHS1+ furnace: Y82E100C20LMPS1AHRI reference: 21574276815.207.80262002.38EPA 3653138

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →