YH536E2S11
LX SERIES · source records, page 4
304 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for YH536E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 304 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 304 / 304 |
| EER2 · BTU/Wh | 10–12 | 304 / 304 |
| HSPF2 · BTU/Wh | 7.8–8.1 | 304 / 304 |
| Cooling capacity · BTU/h | 32,400–35,000 | 304 / 304 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 30,600–32,800 | 304 / 304 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 20,400–22,000 | 304 / 304 |
| Heating capacity at 5°F / −15°C · BTU/h | 17,000–18,400 | 304 / 304 |
| COP at 5°F / −15°C | 2–2.44 | 304 / 304 |
| Equipment / loop type | HP - Split System | 304 / 304 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 304 / 304 |
| Compressor staging | Two-stage | 304 / 304 |
| Connected capability | No | 304 / 304 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTM48C5CFS1+JME16C2SN1AHRI reference: 214426747 | 15.20 | 8.10 | 17500 | 2.42 | EPA 3892891 → |
CTM48C5CFS1+ furnace: Y81E100C16SMPS1AHRI reference: 214426914 | 15.20 | 8.10 | 17800 | 2.40 | EPA 3892892 → |
CTM36C5CDS1+JME16C2SN1AHRI reference: 214426926 | 15.20 | 8.10 | 17600 | 2.44 | EPA 3892893 → |
CTM36C5CDS1+ furnace: Y81E080C16SMPS1AHRI reference: 214426946 | 15.20 | 8.10 | 17400 | 2.42 | EPA 3892894 → |
CTM48C5CFS1+ furnace: Y81E120C16SMPS1AHRI reference: 214426916 | 15.20 | 8.10 | 17700 | 2.40 | EPA 3892895 → |
CTM36C5CDS1+JME12C2SN1AHRI reference: 214426980 | 15.20 | 8.10 | 17600 | 2.42 | EPA 3892896 → |
CTM48C5CFS1+JMVT16CC2N1AHRI reference: 214427272 | 15.20 | 8.10 | 17500 | 2.42 | EPA 3892898 → |
CTM36C5CDS1+JMVT17CC2N1AHRI reference: 214430052 | 15.20 | 8.10 | 17700 | 2.44 | EPA 3892900 → |
CTM48C5CFS1+JMVT17CC2N1AHRI reference: 214427270 | 15.20 | 8.10 | 17500 | 2.44 | EPA 3892901 → |
CTM36C5CDS1+JMVT16CC2N1AHRI reference: 214430054 | 15.20 | 8.10 | 17600 | 2.44 | EPA 3892903 → |
CTM36C5CDS1+JMC16C2SN1AHRI reference: 214430076 | 15.20 | 8.10 | 17600 | 2.44 | EPA 3892904 → |
CTF36C5CDS1+JMVT17CC2N1AHRI reference: 214425784 | 15.20 | 8.10 | 17200 | 2.00 | EPA 3991871 → |
CTM48C5CFS1+ furnace: TL8E100C20UH11AHRI reference: 214426751 | 15.20 | 8.10 | 17300 | 2.00 | EPA 3991921 → |
CTM48C5CFS1+ furnace: TM8Y100C20MP11AHRI reference: 214426773 | 15.20 | 7.80 | 17300 | 2.00 | EPA 3991922 → |
CTM48C5CFS1+ furnace: TM8Y120C20MP11AHRI reference: 214426771 | 15.20 | 7.80 | 17300 | 2.00 | EPA 3991923 → |
CTF48C5CFS1+ furnace: Y81E120C16SMPS1AHRI reference: 214426767 | 15.20 | 8.10 | 17400 | 2.00 | EPA 3991924 → |
CTM48C5CFS1+ furnace: TM8Y100C16MP11AHRI reference: 214426783 | 15.20 | 7.80 | 17300 | 2.00 | EPA 3991925 → |
CTM48C5CFS1+ furnace: TM8Y080C16MP11AHRI reference: 214426785 | 15.20 | 7.80 | 17300 | 2.00 | EPA 3991926 → |
CTF48C5CFS1+ furnace: TM8Y100C16MP11AHRI reference: 214426787 | 15.20 | 7.80 | 17300 | 2.00 | EPA 3991927 → |
CTF48C5CFS1+ furnace: TM8Y080C16MP11AHRI reference: 214426789 | 15.20 | 7.80 | 17300 | 2.00 | EPA 3991928 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →