York / AIR-SOURCE HEAT PUMP

YH536E2S11

LX SERIES · source records, page 3

304 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity32,400–35,000BTU/h

Each efficiency range summarizes published EPA records for YH536E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 304 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16304 / 304
EER2 · BTU/Wh10–12304 / 304
HSPF2 · BTU/Wh7.8–8.1304 / 304
Cooling capacity · BTU/h32,400–35,000304 / 304
Heating capacity at 47°F / 8.3°C · BTU/h30,600–32,800304 / 304
Heating capacity at 17°F / −8.3°C · BTU/h20,400–22,000304 / 304
Heating capacity at 5°F / −15°C · BTU/h17,000–18,400304 / 304
COP at 5°F / −15°C2–2.44304 / 304
Equipment / loop typeHP - Split System304 / 304
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)304 / 304
Compressor stagingTwo-stage304 / 304
Connected capabilityNo304 / 304

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTU48C5XFS1+TXV+ furnace: Y91E080C16SMPS1AHRI reference: 21480756515.207.80172002.00EPA 3627932 →
CTF48C5CFS1+ furnace: Y82E100C20LMPS1AHRI reference: 21574276915.208.10179002.40EPA 3653141 →
CTU48C5XFS1+TXV+ furnace: Y82E100C20LMPS1AHRI reference: 21574277015.208.10179002.40EPA 3653142 →
CTF48C5CFS1+ furnace: Y82E100C16LMPS1AHRI reference: 21574277515.208.10180002.38EPA 3653144 →
CTU48C5XFS1+TXV+ furnace: Y82E100C16LMPS1AHRI reference: 21574277615.208.10180002.38EPA 3653145 →
CTF48C5CFS1+ furnace: Y82E120C20LMPS1AHRI reference: 21574277915.208.10181002.38EPA 3653147 →
CTU48C5XFS1+TXV+ furnace: Y82E120C20LMPS1AHRI reference: 21574278015.208.10181002.38EPA 3653148 →
CTM36C5CDS1+ furnace: Y82E080C16LMPS1AHRI reference: 21643757815.208.10174002.42EPA 3814999 →
CTM48D5CFS1+JMVT20DC2N1AHRI reference: 21643760415.208.10177002.44EPA 3815000 →
CTM48D5CFS1+JMC20D2SN1AHRI reference: 21643760515.208.10177002.44EPA 3815001 →
CTM48C5CFS1+ furnace: Y82E100C20LMPS1AHRI reference: 21643760615.208.10179002.40EPA 3815002 →
CTM48D5CFS1+JME18D2SN1AHRI reference: 21643760715.208.10176002.42EPA 3815003 →
CTM48C5CFS1+ furnace: Y82E080C16LMPS1AHRI reference: 21643760915.208.10180002.38EPA 3815004 →
CTM48C5CFS1+ furnace: Y82E100C16LMPS1AHRI reference: 21643761115.208.10180002.38EPA 3815005 →
CTM48C5CFS1+ furnace: Y82E120C20LMPS1AHRI reference: 21643761215.208.10181002.38EPA 3815006 →
CTM48C5CFS1+JMET16CS2N1AHRI reference: 21442674515.208.10176002.42EPA 3892886 →
CTM48C5CFS1+JME12C2SN1AHRI reference: 21442673915.208.10176002.42EPA 3892887 →
CTM48C5CFS1+JMC16C2SN1AHRI reference: 21442674915.208.10175002.42EPA 3892888 →
CTM48C5CFS1+JMET12CS2N1AHRI reference: 21442674115.208.10176002.42EPA 3892889 →
CTM48C5CFS1+JMC17C2SN1AHRI reference: 21442676315.208.10175002.44EPA 3892890 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →