York / AIR-SOURCE HEAT PUMP

YH536E2S11

LX SERIES · source records, page 11

304 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity32,400–35,000BTU/h

Each efficiency range summarizes published EPA records for YH536E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 304 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16304 / 304
EER2 · BTU/Wh10–12304 / 304
HSPF2 · BTU/Wh7.8–8.1304 / 304
Cooling capacity · BTU/h32,400–35,000304 / 304
Heating capacity at 47°F / 8.3°C · BTU/h30,600–32,800304 / 304
Heating capacity at 17°F / −8.3°C · BTU/h20,400–22,000304 / 304
Heating capacity at 5°F / −15°C · BTU/h17,000–18,400304 / 304
COP at 5°F / −15°C2–2.44304 / 304
Equipment / loop typeHP - Split System304 / 304
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)304 / 304
Compressor stagingTwo-stage304 / 304
Connected capabilityNo304 / 304

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTF48C5CFS2+ furnace: Y81E100C16SMPS1AHRI reference: 21850172215.208.10175002.00EPA 4639895
CTU48C5XFS2+TXV+ furnace: Y81E080C20LMPS1AHRI reference: 21850172015.208.10176002.00EPA 4639896
CTU48C5XFS2+TXV+ furnace: Y81E080C20SMPS1AHRI reference: 21850171715.208.10176002.00EPA 4639897
CTF48C5CFS2+ furnace: Y81E080C20LMPS1AHRI reference: 21850171415.208.10176002.00EPA 4639898
CTF48C5CFS2+ furnace: Y81E080C20SMPS1AHRI reference: 21850171115.208.10176002.00EPA 4639899
CTU48C5XFS2+TXV+ furnace: TL8E100C20UH11AHRI reference: 21850170915.207.80173002.00EPA 4639900
CTF48C5CFS2+ furnace: TL8E100C20UH11AHRI reference: 21850170615.207.80173002.00EPA 4639901
CTU48C5XFS2+TXV+ furnace: Y91E080C16SMPS1AHRI reference: 21850169815.207.80172002.00EPA 4639902
CTF48C5CFS2+ furnace: Y91E080C16SMPS1AHRI reference: 21850169515.207.80172002.00EPA 4639903
CTU48C5XFS2+TXV+ furnace: Y91E080C20SMPS1AHRI reference: 21850169215.208.10178002.00EPA 4639904
CTF48C5CFS2+ furnace: Y91E080C20SMPS1AHRI reference: 21850169015.208.10178002.00EPA 4639905
CTU48C5XFS2+TXV+ furnace: Y81E120C16LMPS1AHRI reference: 21850167615.208.10174002.00EPA 4639906
CTU48C5XFS2+TXV+ furnace: Y81E120C16SMPS1AHRI reference: 21850167415.208.10174002.00EPA 4639907
CTF48C5CFS2+ furnace: Y81E120C16LMPS1AHRI reference: 21850167115.208.10174002.00EPA 4639908
CTF48C5CFS2+ furnace: Y81E120C16SMPS1AHRI reference: 21850166815.208.10174002.00EPA 4639909
CTU48C5XFS2+JMC17C2SN1+TXVAHRI reference: 21850166515.208.10173002.00EPA 4639910
CTF48C5CFS2+JMC17C2SN1AHRI reference: 21850166315.208.10173002.00EPA 4639911
CTU48C5XFS2+JMC16C2SN1+TXVAHRI reference: 21850164415.208.10172002.00EPA 4639912
CTF48C5CFS2+JMC16C2SN1AHRI reference: 21850164115.208.10172002.00EPA 4639913
CTU48C5XFS2+TXV+ furnace: Y82E120C20LMPS1AHRI reference: 21850163915.208.10181002.38EPA 4639914