YH536E2S11
LX SERIES · source records, page 10
304 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for YH536E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 304 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 304 / 304 |
| EER2 · BTU/Wh | 10–12 | 304 / 304 |
| HSPF2 · BTU/Wh | 7.8–8.1 | 304 / 304 |
| Cooling capacity · BTU/h | 32,400–35,000 | 304 / 304 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 30,600–32,800 | 304 / 304 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 20,400–22,000 | 304 / 304 |
| Heating capacity at 5°F / −15°C · BTU/h | 17,000–18,400 | 304 / 304 |
| COP at 5°F / −15°C | 2–2.44 | 304 / 304 |
| Equipment / loop type | HP - Split System | 304 / 304 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 304 / 304 |
| Compressor staging | Two-stage | 304 / 304 |
| Connected capability | No | 304 / 304 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTM48C5CFS1+ furnace: TL9E080C16UH11AHRI reference: 214426737 | 15.20 | 7.80 | 17600 | 2.00 | EPA 4570811 → |
CTF48C5CFS1+ furnace: TL9E080C16UH11AHRI reference: 214426735 | 15.20 | 7.80 | 17600 | 2.00 | EPA 4570812 → |
JHE36C5CD2SS2AHRI reference: 218456683 | 15.20 | 7.80 | 17000 | 2.30 | EPA 4639391 → |
JHE42C5CF2SS2AHRI reference: 218456682 | 15.20 | 8.10 | 17300 | 2.00 | EPA 4639392 → |
JHE36B5CD2SS2AHRI reference: 218456681 | 15.20 | 8.10 | 17600 | 2.00 | EPA 4639393 → |
CTM48D5CFS2+JMC20D2SN1AHRI reference: 218501805 | 15.20 | 8.10 | 17700 | 2.44 | EPA 4639876 → |
CTM48D5CFS2+JMVT20DC2N1AHRI reference: 218501802 | 15.20 | 8.10 | 17700 | 2.44 | EPA 4639877 → |
CTU48C5XFS2+TXV+ furnace: Y82V120C20SMPC1AHRI reference: 218501800 | 15.20 | 8.10 | 17700 | 2.42 | EPA 4639878 → |
CTF48C5CFS2+ furnace: Y82V120C20SMPC1AHRI reference: 218501798 | 15.20 | 8.10 | 17700 | 2.42 | EPA 4639879 → |
CTU48C5XFS2+TXV+ furnace: Y82V100C20SMPC1AHRI reference: 218501795 | 15.20 | 8.10 | 17800 | 2.40 | EPA 4639880 → |
CTF48C5CFS2+ furnace: Y82V100C20SMPC1AHRI reference: 218501793 | 15.20 | 8.10 | 17800 | 2.40 | EPA 4639881 → |
CTU48C5XFS2+TXV+ furnace: TL9E080C16UH11AHRI reference: 218501779 | 15.20 | 7.80 | 17600 | 2.00 | EPA 4639886 → |
CTF48C5CFS2+ furnace: TL9E080C16UH11AHRI reference: 218501777 | 15.20 | 7.80 | 17600 | 2.00 | EPA 4639887 → |
CTU48C5XFS2+JMVT16CC2N1+TXVAHRI reference: 218501741 | 15.20 | 8.10 | 17500 | 2.00 | EPA 4639888 → |
CTF48C5CFS2+JMVT16CC2N1AHRI reference: 218501739 | 15.20 | 8.10 | 17500 | 2.00 | EPA 4639889 → |
CTU48C5XFS2+JMVT17CC2N1+TXVAHRI reference: 218501736 | 15.20 | 8.10 | 17200 | 2.00 | EPA 4639890 → |
CTF48C5CFS2+JMVT17CC2N1AHRI reference: 218501733 | 15.20 | 8.10 | 17200 | 2.00 | EPA 4639891 → |
CTU48C5XFS2+TXV+ furnace: Y81E100C16LMPS1AHRI reference: 218501731 | 15.20 | 8.10 | 17500 | 2.00 | EPA 4639892 → |
CTU48C5XFS2+TXV+ furnace: Y81E100C16SMPS1AHRI reference: 218501728 | 15.20 | 8.10 | 17500 | 2.00 | EPA 4639893 → |
CTF48C5CFS2+ furnace: Y81E100C16LMPS1AHRI reference: 218501725 | 15.20 | 8.10 | 17500 | 2.00 | EPA 4639894 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →