YH2F60TB21
LX SERIES · source records, page 9
177 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for YH2F60TB21. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 177 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 177 / 177 |
| EER2 · BTU/Wh | 11–12 | 177 / 177 |
| HSPF2 · BTU/Wh | 7.8–8.1 | 177 / 177 |
| Cooling capacity · BTU/h | 53,000–57,000 | 177 / 177 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 55,000–59,500 | 177 / 177 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 37,400–39,000 | 177 / 177 |
| Heating capacity at 5°F / −15°C · BTU/h | 29,200–32,800 | 177 / 177 |
| COP at 5°F / −15°C | 2–2.46 | 177 / 177 |
| Equipment / loop type | HP - Split System | 177 / 177 |
| Refrigerant / source-reported GWP | R-410A (GWP:2088) | 177 / 177 |
| Compressor staging | Two-stage | 177 / 177 |
| Connected capability | No | 177 / 177 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
XAFD60HXXN1+TXV+ furnace: TMLE080C20MP11AHRI reference: 210341587 | 15.20 | 8.10 | 30800 | 2.22 | EPA 4048631 → |
XAFC60HBCN1+ furnace: Y92E100C20SMPS1AHRI reference: 212413109 | 15.20 | 8.10 | 32000 | 2.32 | EPA 4048634 → |
XAFD60HXXN1+TXV+ furnace: Y81E130D20SMPS1AHRI reference: 212413180 | 15.20 | 8.10 | 31400 | 2.34 | EPA 4048635 → |
XAFD60HBCN1+ furnace: Y81E130D20SMPS1AHRI reference: 212413181 | 15.20 | 8.10 | 31400 | 2.34 | EPA 4048636 → |
XAFD60HXXN1+TXV+ furnace: Y81E120C16SMPS1AHRI reference: 212413194 | 15.20 | 8.10 | 31800 | 2.32 | EPA 4048637 → |
XAFD60HBCN1+ furnace: Y81E120C16SMPS1AHRI reference: 212413195 | 15.20 | 8.10 | 31800 | 2.32 | EPA 4048639 → |
XAFC60HXXN1+TXV+ furnace: Y81E120C16SMPS1AHRI reference: 212413197 | 15.20 | 8.10 | 31800 | 2.32 | EPA 4048649 → |
XAFC60HBCN1+ furnace: Y81E120C16SMPS1AHRI reference: 212413198 | 15.20 | 8.10 | 31800 | 2.32 | EPA 4048650 → |
XAFD60JBCN1+ furnace: Y92E120D20SMPS1AHRI reference: 212413227 | 15.20 | 8.10 | 31600 | 2.32 | EPA 4048651 → |
XAFD60JXXN1+TXV+ furnace: Y81E120C20SMPS1AHRI reference: 212413258 | 15.20 | 8.10 | 31400 | 2.38 | EPA 4048652 → |
XAFD60JBCN1+ furnace: Y81E120C20SMPS1AHRI reference: 212413259 | 15.20 | 8.10 | 31400 | 2.38 | EPA 4048654 → |
XAFD60JXXN1+TXV+ furnace: Y81E100C20SMPS1AHRI reference: 212413260 | 15.20 | 8.10 | 31400 | 2.38 | EPA 4048655 → |
XAFD60JBCN1+ furnace: Y81E100C20SMPS1AHRI reference: 212413261 | 15.20 | 8.10 | 31400 | 2.38 | EPA 4048656 → |
XAFD60JXXN1+TXV+ furnace: Y81E100C16SMPS1AHRI reference: 212413262 | 15.20 | 8.10 | 31400 | 2.36 | EPA 4048658 → |
XAFD60JBCN1+ furnace: Y81E100C16SMPS1AHRI reference: 212413263 | 15.20 | 8.10 | 31400 | 2.36 | EPA 4048659 → |
XAFD60JXXN1+TXV+ furnace: Y81E080C20SMPS1AHRI reference: 212413264 | 15.20 | 8.10 | 31400 | 2.38 | EPA 4048660 → |
XAFD60JBCN1+ furnace: Y81E080C20SMPS1AHRI reference: 212413265 | 15.20 | 8.10 | 31400 | 2.38 | EPA 4048662 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →