York / AIR-SOURCE HEAT PUMP

YH2F60TB21

LX SERIES · source records, page 8

177 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity53,000–57,000BTU/h

Each efficiency range summarizes published EPA records for YH2F60TB21. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 177 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16177 / 177
EER2 · BTU/Wh11–12177 / 177
HSPF2 · BTU/Wh7.8–8.1177 / 177
Cooling capacity · BTU/h53,000–57,000177 / 177
Heating capacity at 47°F / 8.3°C · BTU/h55,000–59,500177 / 177
Heating capacity at 17°F / −8.3°C · BTU/h37,400–39,000177 / 177
Heating capacity at 5°F / −15°C · BTU/h29,200–32,800177 / 177
COP at 5°F / −15°C2–2.46177 / 177
Equipment / loop typeHP - Split System177 / 177
Refrigerant / source-reported GWPR-410A (GWP:2088)177 / 177
Compressor stagingTwo-stage177 / 177
Connected capabilityNo177 / 177

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
XAFD60HBCN1+ furnace: Y81E130D20LMPS1AHRI reference: 21245136315.208.10314002.34EPA 4048588 →
XAFC60HXXN1+TXV+ furnace: Y81E120C16LMPS1AHRI reference: 21245137115.208.10318002.32EPA 4048589 →
XAFC60HBCN1+ furnace: Y81E120C16LMPS1AHRI reference: 21245137415.208.10318002.32EPA 4048591 →
XAFD60JXXN1+TXV+ furnace: Y81E100C16LMPS1AHRI reference: 21245138515.208.10314002.36EPA 4048592 →
XAFD60JBCN1+ furnace: Y81E100C16LMPS1AHRI reference: 21245179215.208.10314002.36EPA 4048593 →
XAFD60HXXN1+TXV+ furnace: Y81E120C16LMPS1AHRI reference: 21245226515.208.10318002.32EPA 4048594 →
XAFD60HBCN1+ furnace: Y81E120C16LMPS1AHRI reference: 21245226915.208.10318002.32EPA 4048595 →
XAFD60JXXN1+TXV+ furnace: TM9Y120D20MP11AHRI reference: 21034154815.208.10312002.18EPA 4048596 →
XAFD60JBCN1+ furnace: TM9Y120D20MP11AHRI reference: 21034154915.208.10312002.18EPA 4048597 →
XAFD60JBCN1+ furnace: Y91E120D20SMPS1AHRI reference: 21464779615.208.10318002.42EPA 4048601 →
XAFD60JXXN1+TXV+ furnace: TM9E120D20MP12AHRI reference: 21034155615.208.10314002.20EPA 4048607 →
XAFD60JBCN1+ furnace: TM9E120D20MP12AHRI reference: 21034155715.208.10314002.20EPA 4048608 →
XAFD60HXXN1+TXV+ furnace: TM9Y120D20MP11AHRI reference: 21034156015.208.10312002.18EPA 4048609 →
XAFD60HBCN1+ furnace: TM9Y120D20MP11AHRI reference: 21034156115.208.10312002.18EPA 4048610 →
XAHC60HXXN1+TXV+ furnace: TM9E100C20MP12AHRI reference: 21034156915.208.10308002.02EPA 4048611 →
XAHC60HBCN1+ furnace: TM9E100C20MP12AHRI reference: 21034157015.208.10308002.02EPA 4048612 →
XAFD60HXXN1+TXV+ furnace: TM9E080C20MP12AHRI reference: 21034157115.208.10312002.20EPA 4048613 →
XAFD60HBCN1+ furnace: TM9E080C20MP12AHRI reference: 21034157215.208.10312002.20EPA 4048614 →
XAHD60HBCN1+ furnace: TM8Y120C20MP11AHRI reference: 21034157615.208.10306002.00EPA 4048617 →
XAHD60HBCN1+ furnace: TM8Y100C20MP11AHRI reference: 21034157715.208.10306002.00EPA 4048618 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →