Heating performance & equipment details
Ranges include the 407 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18 | 407 / 407 |
| EER2 · BTU/Wh | 11–12 | 407 / 407 |
| HSPF2 · BTU/Wh | 8.1–8.5 | 407 / 407 |
| Cooling capacity · BTU/h | 43,500–54,000 | 407 / 407 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 44,000–53,500 | 407 / 407 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 40,000–45,500 | 407 / 407 |
| Heating capacity at 5°F / −15°C · BTU/h | 33,600–40,000 | 407 / 407 |
| COP at 5°F / −15°C | 2–2.32 | 407 / 407 |
| Equipment / loop type | HP - Split System | 407 / 407 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 407 / 407 |
| Compressor staging | Two-stage | 407 / 407 |
| Connected capability | No | 407 / 407 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTM60C5CGS2+ furnace: Y82V120C20SMPC1AHRI reference: 218641462 | 17.50 | 8.10 | 33800 | 2.24 | EPA 4664966 → |
CTM60C5CGS2+ furnace: Y82V100C20SMPC1AHRI reference: 218641461 | 17.50 | 8.10 | 33800 | 2.24 | EPA 4664967 → |
CTM60C5CGS2+JME16C2SN2AHRI reference: 218641460 | 17.50 | 8.10 | 35200 | 2.28 | EPA 4664968 → |
CTM60C5CGS2+ furnace: Y81E080C16LMPS1AHRI reference: 218641448 | 17.50 | 8.10 | 34200 | 2.24 | EPA 4664980 → |
CTM60C5CGS2+ furnace: Y81E080C16SMPS1AHRI reference: 218641447 | 17.50 | 8.10 | 34200 | 2.24 | EPA 4664981 → |
CTM60C5CGS2+ furnace: Y81E100C16LMPS1AHRI reference: 218641446 | 17.50 | 8.10 | 33800 | 2.22 | EPA 4664982 → |
CTM60C5CGS2+ furnace: Y81E100C16SMPS1AHRI reference: 218641445 | 17.50 | 8.10 | 33800 | 2.22 | EPA 4664983 → |
JSC48C5CG2SS1Cold climate designationAHRI reference: 218641444 | 17.50 | 8.50 | 34000 | 2.20 | EPA 4664984 → |
CTU60C5XGS2+TXV+ furnace: TM9E080C16MP12AHRI reference: 218688176 | 17.50 | 8.10 | 35200 | 2.20 | EPA 4679007 → |
CTF60C5CGS2+ furnace: TM9E080C16MP12AHRI reference: 218688175 | 17.50 | 8.10 | 35200 | 2.20 | EPA 4679008 → |
CTM60C5CGS2+ furnace: TM9E080C16MP12AHRI reference: 218688174 | 17.50 | 8.10 | 35200 | 2.20 | EPA 4679009 → |
CTM60C5CGS2+ furnace: YP9C100C20MP13AHRI reference: 218688169 | 17.50 | 8.10 | 34200 | 2.22 | EPA 4679014 → |
CTM60C5CGS2+ furnace: TP9C100C20MP13AHRI reference: 218688168 | 17.50 | 8.10 | 34200 | 2.22 | EPA 4679015 → |
CTM60C5CGS2+ furnace: TM9V100C20MP12AHRI reference: 218688167 | 17.50 | 8.10 | 34200 | 2.22 | EPA 4679016 → |
CTU60C5XGS2+TXV+ furnace: YPLC120C20MP13AHRI reference: 218688164 | 17.50 | 8.10 | 34000 | 2.20 | EPA 4679019 → |
CTU60C5XGS2+TXV+ furnace: YPLC100C20MP13AHRI reference: 218688163 | 17.50 | 8.10 | 34000 | 2.20 | EPA 4679020 → |
CTU60C5XGS2+TXV+ furnace: TPLC120C20MP13AHRI reference: 218688162 | 17.50 | 8.10 | 34000 | 2.20 | EPA 4679021 → |
CTU60C5XGS2+TXV+ furnace: TPLC100C20MP13AHRI reference: 218688161 | 17.50 | 8.10 | 34000 | 2.20 | EPA 4679022 → |
CTU60C5XGS2+TXV+ furnace: TMLV120C20MP12AHRI reference: 218688160 | 17.50 | 8.10 | 34000 | 2.20 | EPA 4679023 → |
CTU60C5XGS2+TXV+ furnace: TM8V100C20MP12AHRI reference: 218688159 | 17.50 | 8.10 | 34000 | 2.20 | EPA 4679024 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →