HH860E2S12
LX SERIES · source records, page 4
407 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for HH860E2S12. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 407 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18 | 407 / 407 |
| EER2 · BTU/Wh | 11–12 | 407 / 407 |
| HSPF2 · BTU/Wh | 8.1–8.5 | 407 / 407 |
| Cooling capacity · BTU/h | 43,500–54,000 | 407 / 407 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 44,000–53,500 | 407 / 407 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 40,000–45,500 | 407 / 407 |
| Heating capacity at 5°F / −15°C · BTU/h | 33,600–40,000 | 407 / 407 |
| COP at 5°F / −15°C | 2–2.32 | 407 / 407 |
| Equipment / loop type | HP - Split System | 407 / 407 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 407 / 407 |
| Compressor staging | Two-stage | 407 / 407 |
| Connected capability | No | 407 / 407 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTF60D5CGS2+JME18D2SN2Cold climate designationAHRI reference: 218641493 | 17.50 | 8.50 | 36000 | 2.32 | EPA 4664935 → |
CTM60D5CGS2+JMC20D2SN1AHRI reference: 218641492 | 17.50 | 8.10 | 35200 | 2.30 | EPA 4664936 → |
CTF60D5CGS2+JMC20D2SN1AHRI reference: 218641490 | 17.50 | 8.10 | 34800 | 2.28 | EPA 4664938 → |
JSE48D5CG2SS1AHRI reference: 218641489 | 17.50 | 8.10 | 34200 | 2.26 | EPA 4664939 → |
JHC48D5CG2SS1AHRI reference: 218641488 | 17.50 | 8.10 | 34200 | 2.26 | EPA 4664940 → |
JSC48D5CG2SS1AHRI reference: 218641487 | 17.50 | 8.10 | 34200 | 2.26 | EPA 4664941 → |
CTM60C5CGS2+JMC17C2SN1AHRI reference: 218641486 | 17.50 | 8.10 | 34200 | 2.26 | EPA 4664942 → |
CTM60C5CGS2+ furnace: Y82E100C16LMPS1AHRI reference: 218641483 | 17.50 | 8.10 | 34200 | 2.24 | EPA 4664945 → |
CTM60C5CGS2+ furnace: Y81E120C16LMPS1AHRI reference: 218641480 | 17.50 | 8.10 | 34600 | 2.26 | EPA 4664948 → |
CTM60C5CGS2+ furnace: Y81E120C16SMPS1AHRI reference: 218641479 | 17.50 | 8.10 | 34600 | 2.26 | EPA 4664949 → |
CTU60C5XGS2+TXV+ furnace: Y82E100C16LMPS1AHRI reference: 218641478 | 17.50 | 8.10 | 33600 | 2.22 | EPA 4664950 → |
CTF60C5CGS2+ furnace: Y82E100C16LMPS1AHRI reference: 218641477 | 17.50 | 8.10 | 33600 | 2.22 | EPA 4664951 → |
CTU60C5XGS2+TXV+ furnace: Y81E120C16LMPS1AHRI reference: 218641474 | 17.50 | 8.10 | 34600 | 2.26 | EPA 4664954 → |
CTU60C5XGS2+TXV+ furnace: Y81E120C16SMPS1AHRI reference: 218641473 | 17.50 | 8.10 | 34600 | 2.26 | EPA 4664955 → |
CTF60C5CGS2+ furnace: Y81E120C16LMPS1AHRI reference: 218641472 | 17.50 | 8.10 | 34600 | 2.26 | EPA 4664956 → |
CTF60C5CGS2+ furnace: Y81E120C16SMPS1AHRI reference: 218641471 | 17.50 | 8.10 | 34600 | 2.26 | EPA 4664957 → |
CTU60C5XGS2+TXV+ furnace: Y82V120C20SMPC1AHRI reference: 218641468 | 17.50 | 8.10 | 33800 | 2.24 | EPA 4664960 → |
CTF60C5CGS2+ furnace: Y82V120C20SMPC1AHRI reference: 218641467 | 17.50 | 8.10 | 33800 | 2.24 | EPA 4664961 → |
CTU60C5XGS2+TXV+ furnace: Y82V100C20SMPC1AHRI reference: 218641466 | 17.50 | 8.10 | 34000 | 2.22 | EPA 4664962 → |
CTF60C5CGS2+ furnace: Y82V100C20SMPC1AHRI reference: 218641465 | 17.50 | 8.10 | 34000 | 2.22 | EPA 4664963 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →