York / AIR-SOURCE HEAT PUMP

HH836E2S11

LX SERIES · source records, page 29

927 published source records · source checked Sep 21, 2026

SEER2 range15.2–19BTU/Wh
HSPF2 range8–9.5BTU/Wh
Cooling capacity31,600–35,000BTU/h

Each efficiency range summarizes published EPA records for HH836E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 927 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–19927 / 927
EER2 · BTU/Wh10–12927 / 927
HSPF2 · BTU/Wh8–9.5927 / 927
Cooling capacity · BTU/h31,600–35,000927 / 927
Heating capacity at 47°F / 8.3°C · BTU/h30,000–33,000927 / 927
Heating capacity at 17°F / −8.3°C · BTU/h25,400–29,600927 / 927
Heating capacity at 5°F / −15°C · BTU/h22,200–27,200927 / 927
COP at 5°F / −15°C2–2.1927 / 927
Equipment / loop typeHP - Split System927 / 927
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)927 / 927
Compressor stagingContinuously variable927 / 927
Connected capabilityNo927 / 927

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTF36C5CDS1+ furnace: Y82V080C16SMPC1Cold climate designationAHRI reference: 21744394318.009.00234002.00EPA 4044807 →
CTF36B5CDS1+ furnace: Y82V080B12SMPC1Cold climate designationAHRI reference: 21744394418.009.00228002.00EPA 4044808 →
CTU36B5XDS1+TXV+ furnace: Y82V080B12SMPC1Cold climate designationAHRI reference: 21744394518.009.00228002.00EPA 4044809 →
CTM36C5CDS1+ furnace: Y82V100C16SMPC1Cold climate designationAHRI reference: 21744393518.008.50232002.00EPA 4044848 →
CTF30A5ADS1+ furnace: TMLE060A12MP11AHRI reference: 21650871418.008.00254002.00EPA 4639532 →
CTF30A5ADS1+ furnace: TM8E060A12MP11AHRI reference: 21650871318.008.00254002.00EPA 4639533 →
CTF30A5ADS1+ furnace: TL8E060A12UH11AHRI reference: 21650871218.008.00254002.00EPA 4639534 →
CTM36C5ADS2+ furnace: Y91E080C20SMPS1AHRI reference: 21850331318.008.50264002.00EPA 4639547 →
CTM36C5CDS2+ furnace: Y81E120C20LMPS1AHRI reference: 21850331018.008.50262002.00EPA 4639548 →
CTM36C5CDS2+ furnace: Y81E120C20SMPS1AHRI reference: 21850329718.008.50262002.00EPA 4639549 →
CTM36C5ADS2+ furnace: Y81E120C20LMPS1AHRI reference: 21850329418.008.50262002.00EPA 4639550 →
CTM36C5ADS2+ furnace: Y81E120C20SMPS1AHRI reference: 21850329218.008.50262002.00EPA 4639551 →
CTM36C5CDS2+ furnace: Y81E100C16LMPS1AHRI reference: 21850328818.008.50260002.00EPA 4639552 →
CTM36C5CDS2+ furnace: Y81E100C16SMPS1AHRI reference: 21850328518.008.50260002.00EPA 4639553 →
CTM36C5ADS2+ furnace: Y81E100C16LMPS1AHRI reference: 21850328218.008.50260002.00EPA 4639554 →
CTM36C5ADS2+ furnace: Y81E100C16SMPS1AHRI reference: 21850327918.008.50260002.00EPA 4639555 →
CTM36C5CDS2+ furnace: Y81E100C20LMPS1AHRI reference: 21850326918.008.50262002.00EPA 4639558 →
CTM36C5CDS2+ furnace: Y81E100C20SMPS1AHRI reference: 21850326618.008.50262002.00EPA 4639559 →
CTM36C5ADS2+ furnace: Y81E100C20LMPS1AHRI reference: 21850326318.008.50262002.00EPA 4639560 →
CTM36C5ADS2+ furnace: Y81E100C20SMPS1AHRI reference: 21850326018.008.50262002.00EPA 4639561 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →