HH836E2S11
LX SERIES · source records, page 28
927 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for HH836E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 927 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19 | 927 / 927 |
| EER2 · BTU/Wh | 10–12 | 927 / 927 |
| HSPF2 · BTU/Wh | 8–9.5 | 927 / 927 |
| Cooling capacity · BTU/h | 31,600–35,000 | 927 / 927 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 30,000–33,000 | 927 / 927 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 25,400–29,600 | 927 / 927 |
| Heating capacity at 5°F / −15°C · BTU/h | 22,200–27,200 | 927 / 927 |
| COP at 5°F / −15°C | 2–2.1 | 927 / 927 |
| Equipment / loop type | HP - Split System | 927 / 927 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 927 / 927 |
| Compressor staging | Continuously variable | 927 / 927 |
| Connected capability | No | 927 / 927 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTF36C5CDS1+ furnace: Y81E100C16LMPS1Cold climate designationAHRI reference: 216780742 | 18.00 | 8.50 | 26000 | 2.00 | EPA 4008756 → |
CTF36B5CDS1+ furnace: Y81E080B12LMPS1Cold climate designationAHRI reference: 216780747 | 18.00 | 8.50 | 24800 | 2.00 | EPA 4008757 → |
CTU36B5XDS1+TXV+ furnace: Y81E080B12LMPS1Cold climate designationAHRI reference: 216780752 | 18.00 | 8.50 | 24800 | 2.00 | EPA 4008758 → |
CTM36C5CDS1+ furnace: Y81E080C16LMPS1Cold climate designationAHRI reference: 216779847 | 18.00 | 8.50 | 25400 | 2.00 | EPA 4008759 → |
CTM36C5CDS1+ furnace: Y81E080C20LMPS1Cold climate designationAHRI reference: 216779853 | 18.00 | 8.50 | 26200 | 2.00 | EPA 4008760 → |
CTF36C5CDS1+ furnace: Y81E120C20LMPS1Cold climate designationAHRI reference: 216780037 | 18.00 | 8.50 | 26200 | 2.00 | EPA 4008766 → |
CTF36C5CDS1+ furnace: Y81E120C16LMPS1Cold climate designationAHRI reference: 216780182 | 18.00 | 8.50 | 25800 | 2.00 | EPA 4008772 → |
CTF36B5CDS1+ furnace: Y81E100B12LMPS1Cold climate designationAHRI reference: 216780233 | 18.00 | 8.50 | 25000 | 2.00 | EPA 4008774 → |
CTU36B5XDS1+TXV+ furnace: Y81E100B12LMPS1Cold climate designationAHRI reference: 216780238 | 18.00 | 8.50 | 25000 | 2.00 | EPA 4008775 → |
CTM36C5CDS1+ furnace: Y81E100C16LMPS1Cold climate designationAHRI reference: 216780243 | 18.00 | 8.50 | 26000 | 2.00 | EPA 4008776 → |
CTM36B5CDS1+ furnace: Y92E080B12SMPS1Cold climate designationAHRI reference: 216374501 | 18.00 | 8.50 | 24000 | 2.00 | EPA 4012748 → |
CTM36B5CDS1+ furnace: Y92E060B12SMPS1Cold climate designationAHRI reference: 216374504 | 18.00 | 8.50 | 24200 | 2.00 | EPA 4012749 → |
CTM36B5CDS1+ furnace: Y81E100B12LMPS1Cold climate designationAHRI reference: 216780661 | 18.00 | 8.50 | 25000 | 2.00 | EPA 4012760 → |
CTM36B5CDS1+ furnace: Y81E080B12LMPS1Cold climate designationAHRI reference: 216779771 | 18.00 | 8.50 | 25600 | 2.00 | EPA 4012761 → |
CTM36B5CDS1+ furnace: Y82E080B12LMPS1Cold climate designationAHRI reference: 216980381 | 18.00 | 8.50 | 24000 | 2.00 | EPA 4012772 → |
CTM36B5CDS1+ furnace: Y82V080B12SMPC1Cold climate designationAHRI reference: 217443937 | 18.00 | 9.00 | 22800 | 2.00 | EPA 4044802 → |
CTM36C5CDS1+ furnace: Y82V100C20SMPC1Cold climate designationAHRI reference: 217443939 | 18.00 | 8.50 | 23000 | 2.00 | EPA 4044803 → |
CTF36C5CDS1+ furnace: Y82V100C16SMPC1Cold climate designationAHRI reference: 217443940 | 18.00 | 9.00 | 23200 | 2.00 | EPA 4044804 → |
CTF36C5CDS1+ furnace: Y82V100C20SMPC1Cold climate designationAHRI reference: 217443941 | 18.00 | 9.00 | 23000 | 2.00 | EPA 4044805 → |
CTF36C5CDS1+ furnace: Y82V120C20SMPC1Cold climate designationAHRI reference: 217443942 | 18.00 | 9.00 | 22800 | 2.00 | EPA 4044806 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →