York / AIR-SOURCE HEAT PUMP

HH836E2S11

LX SERIES · source records, page 21

927 published source records · source checked Sep 21, 2026

SEER2 range15.2–19BTU/Wh
HSPF2 range8–9.5BTU/Wh
Cooling capacity31,600–35,000BTU/h

Each efficiency range summarizes published EPA records for HH836E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 927 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–19927 / 927
EER2 · BTU/Wh10–12927 / 927
HSPF2 · BTU/Wh8–9.5927 / 927
Cooling capacity · BTU/h31,600–35,000927 / 927
Heating capacity at 47°F / 8.3°C · BTU/h30,000–33,000927 / 927
Heating capacity at 17°F / −8.3°C · BTU/h25,400–29,600927 / 927
Heating capacity at 5°F / −15°C · BTU/h22,200–27,200927 / 927
COP at 5°F / −15°C2–2.1927 / 927
Equipment / loop typeHP - Split System927 / 927
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)927 / 927
Compressor stagingContinuously variable927 / 927
Connected capabilityNo927 / 927

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTM36C5ADS2+JME12C2SN2AHRI reference: 21863669519.009.00256002.00EPA 4663762 →
CTU48C5XFS2+JME16C2SN2+TXVAHRI reference: 21863669419.009.00252002.00EPA 4663763 →
CTF48C5CFS2+JME16C2SN2AHRI reference: 21863669319.009.00252002.00EPA 4663764 →
CTM48C5AFS2+JME12C2SN2AHRI reference: 21863687419.009.00252002.00EPA 4663867 →
CTM48C5AFS2+JME16C2SN2AHRI reference: 21863687319.009.00252002.00EPA 4663868 →
CTF48C5AFS2+JME12C2SN2AHRI reference: 21863687219.009.00252002.00EPA 4663869 →
CTF48C5AFS2+JME16C2SN2AHRI reference: 21863687119.009.00252002.00EPA 4663870 →
CTM36B5CDS1+JMC12B2SN1Cold climate designationAHRI reference: 21439569818.009.00248002.00EPA 3437082 →
CTF36C5CDS1+ furnace: Y81E080C16SMPS1Cold climate designationAHRI reference: 21439570318.008.50254002.00EPA 3437167 →
CTF36B5CDS1+ furnace: Y81E100B12SMPS1Cold climate designationAHRI reference: 21439571218.008.50250002.00EPA 3437168 →
CTF36C5CDS1+ furnace: Y81E120C16SMPS1Cold climate designationAHRI reference: 21439580718.008.50258002.00EPA 3437213 →
CTF36B5CDS1+ furnace: Y81E080B12SMPS1Cold climate designationAHRI reference: 21439601218.008.50248002.00EPA 3437323 →
CTM36C5CDS1+ furnace: Y81E120C16SMPS1Cold climate designationAHRI reference: 21439601418.008.50258002.00EPA 3437324 →
CTM36C5CDS1+ furnace: Y81E100C16SMPS1Cold climate designationAHRI reference: 21439611818.008.50260002.00EPA 3437409 →
CTF36C5CDS1+ furnace: Y81E100C16SMPS1Cold climate designationAHRI reference: 21439619718.008.50260002.00EPA 3437473 →
CTM36C5CDS1+ furnace: Y81E080C16SMPS1Cold climate designationAHRI reference: 21439620218.008.50254002.00EPA 3437475 →
CTM36B5CDS1+ furnace: TM8Y080B12MP11Cold climate designationAHRI reference: 21439590018.008.50256002.00EPA 3557437 →
CTM36B5CDS1+ furnace: TM8E100B12MP11Cold climate designationAHRI reference: 21439610218.008.50250002.00EPA 3557529 →
CTM36B5CDS1+ furnace: TMLE100B12MP11Cold climate designationAHRI reference: 21439610318.008.50250002.00EPA 3557530 →
CTU36B5XDS1+TXV+ furnace: Y81E100B12SMPS1Cold climate designationAHRI reference: 21480737618.008.50250002.00EPA 3557717 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →