HH836E2S11
LX SERIES · source records, page 20
927 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for HH836E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 927 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19 | 927 / 927 |
| EER2 · BTU/Wh | 10–12 | 927 / 927 |
| HSPF2 · BTU/Wh | 8–9.5 | 927 / 927 |
| Cooling capacity · BTU/h | 31,600–35,000 | 927 / 927 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 30,000–33,000 | 927 / 927 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 25,400–29,600 | 927 / 927 |
| Heating capacity at 5°F / −15°C · BTU/h | 22,200–27,200 | 927 / 927 |
| COP at 5°F / −15°C | 2–2.1 | 927 / 927 |
| Equipment / loop type | HP - Split System | 927 / 927 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 927 / 927 |
| Compressor staging | Continuously variable | 927 / 927 |
| Connected capability | No | 927 / 927 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTM48C5AFS2+ furnace: Y81E100C20LMPS1AHRI reference: 218585016 | 19.00 | 9.00 | 25400 | 2.00 | EPA 4651055 → |
CTM48C5AFS2+ furnace: Y81E100C20SMPS1AHRI reference: 218585013 | 19.00 | 9.00 | 25400 | 2.00 | EPA 4651056 → |
CTM48C5AFS2+ furnace: TL8E100C20UH11AHRI reference: 218585010 | 19.00 | 9.00 | 25400 | 2.00 | EPA 4651057 → |
CTM48C5AFS2+ furnace: TL8E080C16UH11AHRI reference: 218585007 | 19.00 | 9.00 | 25600 | 2.00 | EPA 4651058 → |
CTM48C5AFS2+ furnace: Y92E100C16SMPS1AHRI reference: 218585001 | 19.00 | 9.50 | 23400 | 2.00 | EPA 4651060 → |
CTM48C5AFS2+ furnace: Y92E080C16SMPS1AHRI reference: 218584998 | 19.00 | 9.50 | 24200 | 2.00 | EPA 4651061 → |
CTF36C5CDS2+JME16C2SN2AHRI reference: 218636709 | 19.00 | 9.00 | 25600 | 2.00 | EPA 4663748 → |
CTF36C5ADS2+JME16C2SN2AHRI reference: 218636708 | 19.00 | 9.00 | 25600 | 2.00 | EPA 4663749 → |
CTM36C5CDS2+JME16C2SN2AHRI reference: 218636707 | 19.00 | 9.00 | 25600 | 2.00 | EPA 4663750 → |
CTM36C5ADS2+JME16C2SN2AHRI reference: 218636706 | 19.00 | 9.00 | 25600 | 2.00 | EPA 4663751 → |
CTM48C5CFS2+JME12C2SN2AHRI reference: 218636705 | 19.00 | 9.00 | 25200 | 2.00 | EPA 4663752 → |
CTF36C5CDS2+JME12C2SN2AHRI reference: 218636704 | 19.00 | 9.00 | 25600 | 2.00 | EPA 4663753 → |
CTF36C5ADS2+JME12C2SN2AHRI reference: 218636703 | 19.00 | 9.00 | 25600 | 2.00 | EPA 4663754 → |
CTM48C5CFS2+JME16C2SN2AHRI reference: 218636702 | 19.00 | 9.00 | 25200 | 2.00 | EPA 4663755 → |
CTU36B5XDS2+JME12B2SN2+TXVAHRI reference: 218636701 | 19.00 | 9.00 | 25800 | 2.00 | EPA 4663756 → |
CTF36B5CDS2+JME12B2SN2AHRI reference: 218636700 | 19.00 | 9.00 | 25800 | 2.00 | EPA 4663757 → |
CTF36B5ADS2+JME12B2SN2AHRI reference: 218636699 | 19.00 | 9.00 | 25800 | 2.00 | EPA 4663758 → |
CTU48C5XFS2+JME12C2SN2+TXVAHRI reference: 218636698 | 19.00 | 9.00 | 25200 | 2.00 | EPA 4663759 → |
CTF48C5CFS2+JME12C2SN2AHRI reference: 218636697 | 19.00 | 9.00 | 25200 | 2.00 | EPA 4663760 → |
CTM36C5CDS2+JME12C2SN2AHRI reference: 218636696 | 19.00 | 9.00 | 25600 | 2.00 | EPA 4663761 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →