Trane / AIR-SOURCE HEAT PUMP

N5HP5042A1

Advantage 15 Heat Pump · source records, page 4

72 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity38,000–41,000BTU/h

Each efficiency range summarizes published EPA records for N5HP5042A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 72 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–1672 / 72
EER2 · BTU/Wh11.7–1272 / 72
HSPF2 · BTU/Wh7.8–8.172 / 72
Cooling capacity · BTU/h38,000–41,00072 / 72
Heating capacity at 47°F / 8.3°C · BTU/h37,600–39,00072 / 72
Heating capacity at 17°F / −8.3°C · BTU/h25,200–26,20072 / 72
Heating capacity at 5°F / −15°C · BTU/h19,100–19,90072 / 72
COP at 5°F / −15°C2.11–2.2872 / 72
Equipment / loop typeHP - Split System72 / 72
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)72 / 72
Compressor stagingSingle stage72 / 72
Connected capabilityNo72 / 72

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5PX*C005AS3+TSTAT+P0V0C000M50SDAHRI reference: 21846971815.508.10191002.19EPA 4621729
5PX*B006AS3+TSTAT+ furnace: A801X060BM4SDAHRI reference: 21846971215.508.10193002.18EPA 4621731
5PX*B006AS3+TSTAT+ furnace: A952V080BU4SBAHRI reference: 21846971015.508.10195002.17EPA 4621733
5PX*B006AS3+TSTAT+ furnace: A952V060BU4SBAHRI reference: 21846970915.508.10194002.15EPA 4621734
5PX*B006AS3+TSTAT+ furnace: A951X080BU4SAAHRI reference: 21846970815.508.10196002.15EPA 4621735
5PX*B006AS3+TSTAT+ furnace: A801X080BM4SDAHRI reference: 21846970715.508.10195002.16EPA 4621736
5TXCB004AS3+TSTAT+P0V0B000M40SDAHRI reference: 21847001515.207.80192002.17EPA 4621627
A5AHC007A1D3+TDR+TSTATAHRI reference: 21846979615.208.10192002.28EPA 4621669
A5AHC006A1D3+TDR+TSTATAHRI reference: 21846979515.208.10192002.24EPA 4621670
A5AHC005A1D3+TDR+TSTATAHRI reference: 21846979415.208.10191002.11EPA 4621671
5TXCD010AS3+TSTATAHRI reference: 21846978915.208.10199002.14EPA 4621673
5PX*D010AS3+TSTATAHRI reference: 21846975315.208.10199002.14EPA 4621700

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →