Trane / AIR-SOURCE HEAT PUMP

N5HP5042A1

Advantage 15 Heat Pump · source records, page 2

72 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity38,000–41,000BTU/h

Each efficiency range summarizes published EPA records for N5HP5042A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 72 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–1672 / 72
EER2 · BTU/Wh11.7–1272 / 72
HSPF2 · BTU/Wh7.8–8.172 / 72
Cooling capacity · BTU/h38,000–41,00072 / 72
Heating capacity at 47°F / 8.3°C · BTU/h37,600–39,00072 / 72
Heating capacity at 17°F / −8.3°C · BTU/h25,200–26,20072 / 72
Heating capacity at 5°F / −15°C · BTU/h19,100–19,90072 / 72
COP at 5°F / −15°C2.11–2.2872 / 72
Equipment / loop typeHP - Split System72 / 72
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)72 / 72
Compressor stagingSingle stage72 / 72
Connected capabilityNo72 / 72

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5PX*D010AS3+TSTAT+ furnace: A952V120DU5SBAHRI reference: 21846975116.008.10192002.23EPA 4621702
5PX*D010AS3+TSTAT+ furnace: A951X120DU5SAAHRI reference: 21846975016.008.10193002.23EPA 4621703
5PX*D010AS3+TSTAT+ furnace: A801X120DM5SDAHRI reference: 21846974916.008.10194002.22EPA 4621704
5PX*D008AS3+TSTAT+ furnace: A801X120DM5SDAHRI reference: 21846974716.008.10195002.17EPA 4621705
5PX*D008AS3+TSTAT+ furnace: A951X120DU5SAAHRI reference: 21846974616.008.10194002.18EPA 4621706
5PX*D008AS3+TSTAT+ furnace: A952V120DU5SBAHRI reference: 21846974516.008.10193002.21EPA 4621707
5PX*D008AS3+TSTAT+P0V0D000M50SDAHRI reference: 21846974416.008.10193002.20EPA 4621708
5PX*CD09AS3+TSTAT+P0V0C000M50SDAHRI reference: 21846974316.008.10193002.18EPA 4621709
5PX*CD09AS3+TSTAT+ furnace: A801X080CM5SDAHRI reference: 21846974216.008.10196002.14EPA 4621710
5PX*CD09AS3+TSTAT+ furnace: A801X100CM5SDAHRI reference: 21846974116.008.10197002.12EPA 4621711
5PX*CD09AS3+TSTAT+ furnace: A952V100CD5SBAHRI reference: 21846973916.008.10193002.17EPA 4621713
5PX*C009AS3+TSTAT+P0V0C000M50SDAHRI reference: 21846973416.008.10192002.22EPA 4621714
5PX*C009AS3+TSTAT+ furnace: L8V1C100U5VSBAHRI reference: 21846973316.008.10193002.22EPA 4621715
5PX*C009AS3+TSTAT+ furnace: A952V100CU5SBAHRI reference: 21846973216.008.10193002.22EPA 4621716
5PX*C009AS3+TSTAT+ furnace: A952V080CU5SBAHRI reference: 21846973116.008.10194002.21EPA 4621717
5PX*C009AS3+TSTAT+ furnace: A951X100CU5SAAHRI reference: 21846973016.008.10195002.19EPA 4621718
5PX*C009AS3+TSTAT+ furnace: A951X080CU5SAAHRI reference: 21846972916.008.10192002.23EPA 4621719
5PX*C009AS3+TSTAT+ furnace: A801X100CM5SDAHRI reference: 21846972816.008.10197002.17EPA 4621720
5PX*C009AS3+TSTAT+ furnace: A801X080CM5SDAHRI reference: 21846972716.008.10196002.18EPA 4621721
5PX*C007AS3+TSTAT+ furnace: A801X100CM5SDAHRI reference: 21846972516.008.10195002.17EPA 4621723

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →