Trane / AIR-SOURCE HEAT PUMP

N5HP5036A1

Advantage 15 Heat Pump · source records, page 3

83 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range8.1BTU/Wh
Cooling capacity32,200–35,000BTU/h

Each efficiency range summarizes published EPA records for N5HP5036A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 83 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–1683 / 83
EER2 · BTU/Wh11.7–1283 / 83
HSPF2 · BTU/Wh8.183 / 83
Cooling capacity · BTU/h32,200–35,00083 / 83
Heating capacity at 47°F / 8.3°C · BTU/h29,600–31,20083 / 83
Heating capacity at 17°F / −8.3°C · BTU/h21,400–22,40083 / 83
Heating capacity at 5°F / −15°C · BTU/h17,100–17,80083 / 83
COP at 5°F / −15°C2.29–2.4883 / 83
Equipment / loop typeHP - Split System83 / 83
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)83 / 83
Compressor stagingSingle stage83 / 83
Connected capabilityNo83 / 83

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5PX*C005AS3+TSTAT+ furnace: A801X080CM5SDAHRI reference: 21846961315.508.10175002.32EPA 4621318 →
5PX*C005AS3+TSTAT+P0V0C000M50SDAHRI reference: 21846961215.508.10172002.37EPA 4621319 →
5PX*BD06AS3+TSTAT+ furnace: A801X060AM3SDAHRI reference: 21846960015.508.10176002.33EPA 4621329 →
5PX*B006AS3+TSTAT+ furnace: L8V1A060U3VSBAHRI reference: 21846958815.508.10174002.35EPA 4621332 →
5PX*B006AS3+TSTAT+ furnace: A801X080BM4SDAHRI reference: 21846958715.508.10174002.38EPA 4621333 →
5PX*B006AS3+TSTAT+P0V0A000M30SDAHRI reference: 21846958515.508.10173002.37EPA 4621334 →
5PX*B006AS3+TSTAT+ furnace: A801X060AM3SDAHRI reference: 21846958415.508.10176002.34EPA 4621335 →
5PX*B006AS3+TSTAT+ furnace: L8V1B080U4VSBAHRI reference: 21846958215.508.10175002.36EPA 4621337 →
5PX*B006AS3+TSTAT+ furnace: A951X040BU3SAAHRI reference: 21846958115.508.10173002.37EPA 4621338 →
5PX*B006AS3+TSTAT+ furnace: A951X060BU4SAAHRI reference: 21846958015.508.10175002.36EPA 4621339 →
5PX*B006AS3+TSTAT+ furnace: A951X080BU4SAAHRI reference: 21846957915.508.10175002.37EPA 4621340 →
5PX*B006AS3+TSTAT+ furnace: A952V040BU3SBAHRI reference: 21846957815.508.10173002.37EPA 4621341 →
5PX*B006AS3+TSTAT+ furnace: A952V060BU4SBAHRI reference: 21846957715.508.10174002.37EPA 4621342 →
5PX*B006AS3+TSTAT+ furnace: A952V080BU4SBAHRI reference: 21846957615.508.10175002.37EPA 4621343 →
5PX*B004AS3+TSTAT+P0V0B000M40SDAHRI reference: 21846956915.508.10173002.36EPA 4621347 →
5TXCC005AS3+TSTAT+P0V0C000M50SDAHRI reference: 21846967715.508.10172002.37EPA 4621755 →
5TXCC005AS3+TSTAT+ furnace: A951X080CU5SAAHRI reference: 21846967515.508.10175002.33EPA 4621756 →
5TXCC005AS3+TSTAT+ furnace: A801X080CM5SDAHRI reference: 21846967415.508.10175002.33EPA 4621757 →
5TXCB006AS3+TSTAT+ furnace: A801X060AM3SDAHRI reference: 21846967015.508.10176002.34EPA 4621758 →
5TXCB006AS3+TSTAT+ furnace: A801X080BM4SDAHRI reference: 21846966815.508.10174002.38EPA 4621760 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →