Trane / AIR-SOURCE HEAT PUMP

N5HP5024A1

Advantage 15 Heat Pump · source records, page 2

81 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity22,600–24,200BTU/h

Each efficiency range summarizes published EPA records for N5HP5024A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 81 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–1681 / 81
EER2 · BTU/Wh11.7–1281 / 81
HSPF2 · BTU/Wh7.8–8.181 / 81
Cooling capacity · BTU/h22,600–24,20081 / 81
Heating capacity at 47°F / 8.3°C · BTU/h20,800–22,40081 / 81
Heating capacity at 17°F / −8.3°C · BTU/h14,100–15,20081 / 81
Heating capacity at 5°F / −15°C · BTU/h10,900–11,60081 / 81
COP at 5°F / −15°C2.02–2.2881 / 81
Equipment / loop typeHP - Split System81 / 81
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)81 / 81
Compressor stagingSingle stage81 / 81
Connected capabilityNo81 / 81

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5PX*BD06AS3+TSTAT+ furnace: A801X060AM3SDAHRI reference: 21873676616.008.10113002.17EPA 4704877
5PX*BD06AS3+TSTAT+ furnace: A801X040BM2SDAHRI reference: 21873676416.008.10113002.17EPA 4704879
5PX*BD06AS3+TSTAT+ furnace: A801X040AM3SDAHRI reference: 21873676216.008.10114002.18EPA 4704881
5PX*BD06AS3+TSTAT+P0V0B000M40SDAHRI reference: 21873676016.008.10111002.22EPA 4704883
5PX*BD06AS3+TSTAT+P0V0A000M30SDAHRI reference: 21873675816.008.10113002.18EPA 4704885
5PX*BD06AS3+TSTAT+ furnace: A952V060BD3SBAHRI reference: 21873675616.008.10114002.17EPA 4704887
5PX*BD06AS3+TSTAT+ furnace: A952V040BD3SBAHRI reference: 21873675416.008.10112002.18EPA 4704889
5PX*BD06AS3+TSTAT+ furnace: A951X080BD4SAAHRI reference: 21873675216.008.10113002.17EPA 4704891
5PX*BD06AS3+TSTAT+ furnace: A951X060BD3SAAHRI reference: 21873675016.008.10113002.20EPA 4704893
5PX*B006AS3+TSTAT+ furnace: L8V1B080U4VSBAHRI reference: 21873669416.008.00116002.17EPA 4704899
5PX*B006AS3+TSTAT+ furnace: L8V1A060U3VSBAHRI reference: 21873669216.008.00114002.16EPA 4704901
5PX*B006AS3+TSTAT+ furnace: L8V1A040U3VSBAHRI reference: 21873669016.008.00115002.17EPA 4704903
5PX*B006AS3+TSTAT+P0V0B000M40SDAHRI reference: 21873668816.008.10112002.22EPA 4704905
5PX*B006AS3+TSTAT+P0V0A000M30SDAHRI reference: 21873668616.008.10116002.17EPA 4704907
5PX*B006AS3+TSTAT+ furnace: A952V060BU4SBAHRI reference: 21873668416.008.10114002.19EPA 4704909
5PX*B006AS3+TSTAT+ furnace: A801X040AM3SDAHRI reference: 21873668216.008.00113002.17EPA 4704911
5PX*B006AS3+TSTAT+ furnace: A801X040BM2SDAHRI reference: 21873668016.008.00113002.18EPA 4704913
5PX*B006AS3+TSTAT+ furnace: A952V040BU3SBAHRI reference: 21873667816.008.10114002.18EPA 4704915
5PX*B006AS3+TSTAT+ furnace: A951X080BU4SAAHRI reference: 21873667616.008.10113002.20EPA 4704917
5PX*B006AS3+TSTAT+ furnace: A951X060BU4SAAHRI reference: 21873667416.008.10115002.16EPA 4704919

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →