Trane / AIR-SOURCE HEAT PUMP

N5HP5024A1

Advantage 15 Heat Pump · source records, page 2

81 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity22,600–24,200BTU/h

Each efficiency range summarizes published EPA records for N5HP5024A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 81 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–1681 / 81
EER2 · BTU/Wh11.7–1281 / 81
HSPF2 · BTU/Wh7.8–8.181 / 81
Cooling capacity · BTU/h22,600–24,20081 / 81
Heating capacity at 47°F / 8.3°C · BTU/h20,800–22,40081 / 81
Heating capacity at 17°F / −8.3°C · BTU/h14,100–15,20081 / 81
Heating capacity at 5°F / −15°C · BTU/h10,900–11,60081 / 81
COP at 5°F / −15°C2.02–2.2881 / 81
Equipment / loop typeHP - Split System81 / 81
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)81 / 81
Compressor stagingSingle stage81 / 81
Connected capabilityNo81 / 81

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5PX*BD06AS3+TSTAT+ furnace: A801X060AM3SDAHRI reference: 21873676616.008.10113002.17EPA 4704877 →
5PX*BD06AS3+TSTAT+ furnace: A801X040BM2SDAHRI reference: 21873676416.008.10113002.17EPA 4704879 →
5PX*BD06AS3+TSTAT+ furnace: A801X040AM3SDAHRI reference: 21873676216.008.10114002.18EPA 4704881 →
5PX*BD06AS3+TSTAT+P0V0B000M40SDAHRI reference: 21873676016.008.10111002.22EPA 4704883 →
5PX*BD06AS3+TSTAT+P0V0A000M30SDAHRI reference: 21873675816.008.10113002.18EPA 4704885 →
5PX*BD06AS3+TSTAT+ furnace: A952V060BD3SBAHRI reference: 21873675616.008.10114002.17EPA 4704887 →
5PX*BD06AS3+TSTAT+ furnace: A952V040BD3SBAHRI reference: 21873675416.008.10112002.18EPA 4704889 →
5PX*BD06AS3+TSTAT+ furnace: A951X080BD4SAAHRI reference: 21873675216.008.10113002.17EPA 4704891 →
5PX*BD06AS3+TSTAT+ furnace: A951X060BD3SAAHRI reference: 21873675016.008.10113002.20EPA 4704893 →
5PX*B006AS3+TSTAT+ furnace: L8V1B080U4VSBAHRI reference: 21873669416.008.00116002.17EPA 4704899 →
5PX*B006AS3+TSTAT+ furnace: L8V1A060U3VSBAHRI reference: 21873669216.008.00114002.16EPA 4704901 →
5PX*B006AS3+TSTAT+ furnace: L8V1A040U3VSBAHRI reference: 21873669016.008.00115002.17EPA 4704903 →
5PX*B006AS3+TSTAT+P0V0B000M40SDAHRI reference: 21873668816.008.10112002.22EPA 4704905 →
5PX*B006AS3+TSTAT+P0V0A000M30SDAHRI reference: 21873668616.008.10116002.17EPA 4704907 →
5PX*B006AS3+TSTAT+ furnace: A952V060BU4SBAHRI reference: 21873668416.008.10114002.19EPA 4704909 →
5PX*B006AS3+TSTAT+ furnace: A801X040AM3SDAHRI reference: 21873668216.008.00113002.17EPA 4704911 →
5PX*B006AS3+TSTAT+ furnace: A801X040BM2SDAHRI reference: 21873668016.008.00113002.18EPA 4704913 →
5PX*B006AS3+TSTAT+ furnace: A952V040BU3SBAHRI reference: 21873667816.008.10114002.18EPA 4704915 →
5PX*B006AS3+TSTAT+ furnace: A951X080BU4SAAHRI reference: 21873667616.008.10113002.20EPA 4704917 →
5PX*B006AS3+TSTAT+ furnace: A951X060BU4SAAHRI reference: 21873667416.008.10115002.16EPA 4704919 →