SEER2 range15.2–17BTU/Wh
HSPF2 range8.5–9BTU/Wh
Cooling capacity50,500–53,000BTU/h

Each efficiency range summarizes published EPA records for 5TWX7060A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 147 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17147 / 147
EER2 · BTU/Wh10–11.5147 / 147
HSPF2 · BTU/Wh8.5–9147 / 147
Cooling capacity · BTU/h50,500–53,000147 / 147
Heating capacity at 47°F / 8.3°C · BTU/h50,500–52,000147 / 147
Heating capacity at 17°F / −8.3°C · BTU/h33,400–34,800147 / 147
Heating capacity at 5°F / −15°C · BTU/h38,000–39,500147 / 147
COP at 5°F / −15°C2.1–2.2147 / 147
Equipment / loop typeHP - Split System147 / 147
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)147 / 147
Compressor stagingTwo-stage147 / 147
Connected capabilityNo147 / 147

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5TXCD008AS3+ furnace: S8X2C100M5PTCCold climate designationAHRI reference: 21676511016.508.70390002.10EPA 4513347
5TXCD008AS3+ furnace: S8X2D120M5PSCCold climate designationAHRI reference: 21676511216.508.70390002.10EPA 4513349
5TXCD008AS3+ furnace: S8X2C100M5PSCCold climate designationAHRI reference: 21676511316.508.70390002.10EPA 4513350
5TXCD010AS3+ furnace: S8X2D120M5PSCCold climate designationAHRI reference: 21676511516.508.70385002.20EPA 4513352
5TXCD010AS3+ furnace: S8X2C100M5PSCCold climate designationAHRI reference: 21676511716.509.00385002.10EPA 4513353
5TXCD010AS3+ furnace: S8X2C080M5PSCCold climate designationAHRI reference: 21676511616.509.00385002.20EPA 4513354
5TXCD010AS3+ furnace: S8X1D120M5PTCCold climate designationAHRI reference: 21676511916.508.70385002.20EPA 4513355
5TXCD010AS3+ furnace: S8X1C080M5PTCCold climate designationAHRI reference: 21676511816.509.00385002.20EPA 4513356
5TXCD010AS3+ furnace: S8X2C100M5PTCCold climate designationAHRI reference: 21676512016.509.00385002.10EPA 4513357
5TXCD010AS3+ furnace: S8X2D120M5PTCCold climate designationAHRI reference: 21676512116.508.70385002.20EPA 4513358
5TXCD010AS3+ furnace: S8X1C100M5PTCCold climate designationAHRI reference: 21676512216.509.00385002.10EPA 4513359
5TXCD010AS3+ furnace: S8X2C080M5PTCCold climate designationAHRI reference: 21676512316.509.00385002.20EPA 4513360
5PX*D008AS3+ furnace: S8X2C100M5PSCCold climate designationAHRI reference: 21676508116.508.70390002.10EPA 4513405
5PX*D008AS3+ furnace: S8X1C100M5PTCCold climate designationAHRI reference: 21676508316.508.70390002.10EPA 4513407
5PX*D008AS3+ furnace: S8X2D120M5PSCCold climate designationAHRI reference: 21676508516.508.70390002.10EPA 4513409
5PX*D008AS3+ furnace: S8X2C100M5PTCCold climate designationAHRI reference: 21676508616.508.70390002.10EPA 4513410
5PX*D008AS3+ furnace: S8X1D120M5PTCCold climate designationAHRI reference: 21676508816.508.70390002.10EPA 4513412
5PX*D008AS3+ furnace: S8X2D120M5PTCCold climate designationAHRI reference: 21676508916.508.70390002.10EPA 4513413
5PX*D010AS3+ furnace: S8X1D120M5PTCCold climate designationAHRI reference: 21676509016.509.00385002.20EPA 4513414
5PX*D010AS3+ furnace: S8X2D120M5PTCCold climate designationAHRI reference: 21676509116.509.00385002.20EPA 4513415

Sources and documentation