Trane / AIR-SOURCE HEAT PUMP

5TWX7048A1

17 Multi-Speed Heat Pump with WeatherGuard Top · source records, page 8

220 published source records · source checked Sep 21, 2026

SEER2 range15.2–17.1BTU/Wh
HSPF2 range8.5–9BTU/Wh
Cooling capacity43,000–44,500BTU/h

Each efficiency range summarizes published EPA records for 5TWX7048A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 220 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17.1220 / 220
EER2 · BTU/Wh11.2–12.7220 / 220
HSPF2 · BTU/Wh8.5–9220 / 220
Cooling capacity · BTU/h43,000–44,500220 / 220
Heating capacity at 47°F / 8.3°C · BTU/h43,500–45,500220 / 220
Heating capacity at 17°F / −8.3°C · BTU/h28,800–39,500220 / 220
Heating capacity at 5°F / −15°C · BTU/h31,800–33,200220 / 220
COP at 5°F / −15°C2.1–2.23220 / 220
Equipment / loop typeHP - Split System220 / 220
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)220 / 220
Compressor stagingTwo-stage220 / 220
Connected capabilityNo220 / 220

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5TXCD010AS3+ furnace: S9X1C080U5PSBAHRI reference: 21676719116.008.70320002.19EPA 3983449 →
5TXCD010AS3+ furnace: S9V2C080U5VSBAHRI reference: 21676719316.008.70320002.20EPA 3983451 →
5TXCD010AS3+ furnace: S8V2D120M5PCBAHRI reference: 21676719416.008.70322002.21EPA 3983452 →
5TXCD010AS3+ furnace: S8V2C100M5PCBAHRI reference: 21676719516.008.70320002.20EPA 3983453 →
5TXCD010AS3+ furnace: S8V2C080M5PCBAHRI reference: 21676719616.008.70320002.19EPA 3983454 →
5TXCD010AS3+P0V0D000M50SDAHRI reference: 21676719716.008.70320002.23EPA 3983455 →
5TXCD010AS3+P0V0C000M50SDAHRI reference: 21676719816.008.70320002.22EPA 3983456 →
5PX*D008AS3+P0V0C000M50SDAHRI reference: 21676728016.008.70324002.21EPA 3983545 →
5TAM5D06AC41AHRI reference: 21677011616.008.50318002.16EPA 3983996 →
5TAMXD06AV41AHRI reference: 21677011716.008.70324002.17EPA 3983997 →
5TXCD008AS3+ furnace: *UHMD120CCV5Cold climate designationAHRI reference: 21676447416.009.00332002.10EPA 4513255 →
5PX*D008AS3+ furnace: *UHMD120CCV5Cold climate designationAHRI reference: 21676443516.009.00332002.10EPA 4513300 →
5TXCD010AS3+ furnace: S9X2C080U5PSBAHRI reference: 21676718816.008.70320002.10EPA 4585440 →
5TXCD010AS3+ furnace: S8V2D120M5PDBAHRI reference: 21676718716.008.70322002.20EPA 4585441 →
5TXCD010AS3+ furnace: S8V2C080M5PDBAHRI reference: 21676718616.008.70320002.10EPA 4585442 →
5TXCD010AS3+ furnace: S8V2C100M5PDBAHRI reference: 21676718516.008.70320002.20EPA 4585443 →
5TXCD008AS3+ furnace: S9X1C080U5PSBCold climate designationAHRI reference: 21676718216.008.70332002.10EPA 4585444 →
5TXCD008AS3+ furnace: S8V2D120M5PDBAHRI reference: 21676718016.008.70324002.20EPA 4585445 →
5TXCD008AS3+ furnace: S9X2C080U5PSBCold climate designationAHRI reference: 21676717716.008.70332002.10EPA 4585446 →
5PX*D010AS3+ furnace: S8V2C080M5PDBAHRI reference: 21676714816.008.70322002.10EPA 4585454 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →