Trane / AIR-SOURCE HEAT PUMP

5TWX7048A1

17 Multi-Speed Heat Pump with WeatherGuard Top · source records, page 5

220 published source records · source checked Sep 21, 2026

SEER2 range15.2–17.1BTU/Wh
HSPF2 range8.5–9BTU/Wh
Cooling capacity43,000–44,500BTU/h

Each efficiency range summarizes published EPA records for 5TWX7048A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 220 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17.1220 / 220
EER2 · BTU/Wh11.2–12.7220 / 220
HSPF2 · BTU/Wh8.5–9220 / 220
Cooling capacity · BTU/h43,000–44,500220 / 220
Heating capacity at 47°F / 8.3°C · BTU/h43,500–45,500220 / 220
Heating capacity at 17°F / −8.3°C · BTU/h28,800–39,500220 / 220
Heating capacity at 5°F / −15°C · BTU/h31,800–33,200220 / 220
COP at 5°F / −15°C2.1–2.23220 / 220
Equipment / loop typeHP - Split System220 / 220
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)220 / 220
Compressor stagingTwo-stage220 / 220
Connected capabilityNo220 / 220

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5PX*C009AS3+ furnace: S8X1C080M5PSCAHRI reference: 21676442516.509.00322002.20EPA 3980557
5PX*C009AS3+ furnace: *UHMC100CCV4AHRI reference: 21676442316.509.00322002.10EPA 3980561
5PX*CD09AS3+ furnace: S8X1C080M5PSCAHRI reference: 21676442916.508.70320002.10EPA 3980566
5PX*C009AS3+ furnace: S9V2C100U5PSCCold climate designationAHRI reference: 21676442816.509.00324002.10EPA 3980567
5PX*D008AS3+ furnace: L8V1C100U5VSBAHRI reference: 21676443616.509.00326002.20EPA 3980568
5PX*D008AS3+ furnace: *UHMC100CCV4Cold climate designationAHRI reference: 21676443416.509.00328002.10EPA 3980569
5PX*CD09AS3+ furnace: S9V2C100D5PSCCold climate designationAHRI reference: 21676443216.508.70322002.10EPA 3980570
5PX*CD09AS3+ furnace: S9V2C100D4VSBCold climate designationAHRI reference: 21676443316.508.70322002.10EPA 3980572
5PX*D010AS3+ furnace: *UHMD120CCV5AHRI reference: 21676444316.509.00320002.10EPA 3980575
5PX*D008AS3+ furnace: S9V2C080U5PSCAHRI reference: 21676444016.509.00326002.20EPA 3980583
5PX*DD10AS3+ furnace: S9V2D120D5PSCAHRI reference: 21676445716.509.00324002.10EPA 3980591
5PX*DD10AS3+ furnace: S8X1C080M5PSCAHRI reference: 21676445516.509.00326002.10EPA 3980593
5TXCC009AS3+ furnace: *UHMC100CCV4AHRI reference: 21676446616.509.00322002.10EPA 3980668
5TXCD008AS3+ furnace: S9V2C080U5PSCAHRI reference: 21676447016.509.00326002.20EPA 3980671
5TXCC009AS3+ furnace: S9V2C100U5PSCCold climate designationAHRI reference: 21676446716.509.00324002.10EPA 3980672
5TXCC009AS3+ furnace: S8X1C080M5PSCAHRI reference: 21676446216.509.00322002.20EPA 3980675
5TXCD010AS3+ furnace: L9X1C100U5VSACold climate designationAHRI reference: 21676448116.508.70326002.10EPA 3980676
5TXCD010AS3+ furnace: *UHMD120CCV5AHRI reference: 21676447916.509.00320002.10EPA 3980680
5TXCD008AS3+ furnace: L8V1C100U5VSBAHRI reference: 21676447516.509.00326002.20EPA 3980681
5TXCD008AS3+ furnace: *UHMC100CCV4Cold climate designationAHRI reference: 21676447316.509.00328002.10EPA 3980684

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →