Trane / AIR-SOURCE HEAT PUMP

5TWX7048A1

17 Multi-Speed Heat Pump with WeatherGuard Top · source records, page 11

220 published source records · source checked Sep 21, 2026

SEER2 range15.2–17.1BTU/Wh
HSPF2 range8.5–9BTU/Wh
Cooling capacity43,000–44,500BTU/h

Each efficiency range summarizes published EPA records for 5TWX7048A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 220 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17.1220 / 220
EER2 · BTU/Wh11.2–12.7220 / 220
HSPF2 · BTU/Wh8.5–9220 / 220
Cooling capacity · BTU/h43,000–44,500220 / 220
Heating capacity at 47°F / 8.3°C · BTU/h43,500–45,500220 / 220
Heating capacity at 17°F / −8.3°C · BTU/h28,800–39,500220 / 220
Heating capacity at 5°F / −15°C · BTU/h31,800–33,200220 / 220
COP at 5°F / −15°C2.1–2.23220 / 220
Equipment / loop typeHP - Split System220 / 220
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)220 / 220
Compressor stagingTwo-stage220 / 220
Connected capabilityNo220 / 220

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5TXCC007AS3+ furnace: S8V2C100M5PDBCold climate designationAHRI reference: 21676716015.508.70328002.10EPA 4585450 →
5PX*DD10AS3+ furnace: S8V2D120M5PDBAHRI reference: 21676715715.508.70324002.10EPA 4585451 →
5PX*D010AS3+ furnace: S9X2D120U5PSBCold climate designationAHRI reference: 21676713915.508.70324002.20EPA 4585457 →
5PX*D008AS3+ furnace: S9X2D120U5PSBAHRI reference: 21676712515.508.70326002.20EPA 4585459 →
5PX*D008AS3+ furnace: S8V2C080M5PDBCold climate designationAHRI reference: 21676712315.508.70328002.10EPA 4585460 →
5PX*CD09AS3+ furnace: S8V2C080M5PDBAHRI reference: 21676711515.508.50320002.10EPA 4585462 →
5PX*C009AS3+ furnace: S8V2C080M5PDBCold climate designationAHRI reference: 21676710215.508.70322002.10EPA 4585465 →
5TXCD010AS3+ furnace: S9X2D120U5PSBAHRI reference: 21676720015.508.70324002.20EPA 4586024 →
5TXCD008AS3+ furnace: S9X2D120U5PSBAHRI reference: 21676718415.508.70326002.20EPA 4586025 →
5TXCC009AS3+ furnace: S8V2C100M5PDBAHRI reference: 21676716115.508.70320002.10EPA 4586027 →
5PX*D008AS3+ furnace: S8V2C100M5PDBAHRI reference: 21676712415.508.70326002.10EPA 4586030 →
5PX*CD09AS3+ furnace: S8V2C100M5PDBAHRI reference: 21676711615.508.50320002.10EPA 4586032 →
5PX*C009AS3+ furnace: S8V2C100M5PDBAHRI reference: 21676710315.508.70320002.10EPA 4586033 →
5PX*CD09AS3+ furnace: S9X1C100D5PSBCold climate designationAHRI reference: 21676711715.208.50324002.10EPA 3983382 →
5PX*DD10AS3+ furnace: S9V2D120D5VSBAHRI reference: 21676714915.208.70324002.18EPA 3983400 →
5PX*DD10AS3+ furnace: S9X1D120D5PSBAHRI reference: 21676715515.208.70324002.18EPA 3983404 →
5PX*DD10AS3+ furnace: S8V2C100M5PDBAHRI reference: 21676715615.208.70326002.10EPA 4585452 →
5PX*DD10AS3+ furnace: S9X2D120D5PSBAHRI reference: 21676715415.208.70324002.10EPA 4585453 →
5PX*CD09AS3+ furnace: S9X2C100D5PSBCold climate designationAHRI reference: 21676711415.208.50324002.10EPA 4585463 →
5PX*DD10AS3+ furnace: S8V2C100M5PCBAHRI reference: 21676715115.208.70326002.10EPA 4586028 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →