Trane / AIR-SOURCE HEAT PUMP

5TWX7036A1

17 Multi-Speed Heat Pump with WeatherGuard Top · source records, page 21

519 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range8.1–9.4BTU/Wh
Cooling capacity31,400–34,800BTU/h

Each efficiency range summarizes published EPA records for 5TWX7036A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 519 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18519 / 519
EER2 · BTU/Wh11–12.7519 / 519
HSPF2 · BTU/Wh8.1–9.4519 / 519
Cooling capacity · BTU/h31,400–34,800519 / 519
Heating capacity at 47°F / 8.3°C · BTU/h31,400–33,800519 / 519
Heating capacity at 17°F / −8.3°C · BTU/h20,800–30,200519 / 519
Heating capacity at 5°F / −15°C · BTU/h23,600–25,000519 / 519
COP at 5°F / −15°C1.9–2.2519 / 519
Equipment / loop typeHP - Split System519 / 519
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)519 / 519
Compressor stagingTwo-stage519 / 519
Connected capabilityNo519 / 519

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5TXCC005AS3+ furnace: S9V2C100U5VSBCold climate designationAHRI reference: 21676705616.008.70240002.10EPA 3983216 →
5TXCC005AS3+ furnace: S9V2C080U5VSBCold climate designationAHRI reference: 21676705716.008.70240002.10EPA 3983217 →
5TXCC005AS3+ furnace: S8V2C100M5PCBCold climate designationAHRI reference: 21676705816.008.50240002.10EPA 3983218 →
5TXCC005AS3+ furnace: S8V2C080M5PCBCold climate designationAHRI reference: 21676705916.008.50240002.10EPA 3983219 →
5TXCC005AS3+ furnace: S9X1C080U5PSBCold climate designationAHRI reference: 21676706516.008.70240002.10EPA 3983221 →
5TXCD008AS3+ furnace: S9X1D120U5PSBCold climate designationAHRI reference: 21676709416.009.00240002.20EPA 3983328 →
5TXCD010AS3+ furnace: S9X1D120U5PSBCold climate designationAHRI reference: 21676709716.009.00238002.20EPA 3983330 →
5PX*C009AS3+ furnace: L9X1C100U5VSACold climate designationAHRI reference: 21677009716.008.70238002.10EPA 3983977 →
5TAMXD04AV31Cold climate designationAHRI reference: 21677010816.008.70240002.10EPA 3983988 →
5TXCC009AS3+ furnace: L9X1C100U5VSACold climate designationAHRI reference: 21677011316.008.70238002.10EPA 3983993 →
5PX*C007AS3+ furnace: S9V2C100D5PSCCold climate designationAHRI reference: 21676428616.009.00236002.10EPA 4513238 →
5PX*C007AS3+ furnace: S9V2C100D4VSBCold climate designationAHRI reference: 21676428716.009.00236002.10EPA 4513239 →
5PX*D008AS3+ furnace: *DHMD120CCV5Cold climate designationAHRI reference: 21676432616.009.00236002.10EPA 4513241 →
5TXCB006AS3+ furnace: S9V2B080D4VSBCold climate designationAHRI reference: 21676436116.008.70236002.10EPA 4513270 →
5TXCB006AS3+ furnace: *DHMB060CCV3Cold climate designationAHRI reference: 21676437716.008.70238002.10EPA 4513272 →
5TXCB006AS3+ furnace: *DHMB080CCV3Cold climate designationAHRI reference: 21676437816.008.70236002.10EPA 4513273 →
5TXCB006AS3+ furnace: S9V2B040D3PSCCold climate designationAHRI reference: 21676437916.008.70236002.10EPA 4513274 →
5TXCB006AS3+ furnace: S9V2B060D3PSCCold climate designationAHRI reference: 21676438016.008.70236002.10EPA 4513275 →
5TXCB006AS3+ furnace: S9V2B060D3VSBCold climate designationAHRI reference: 21676438116.008.70236002.10EPA 4513276 →
5TXCB006AS3+ furnace: S9V2B080D4PSCCold climate designationAHRI reference: 21676438216.008.70236002.10EPA 4513277 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →