Trane / AIR-SOURCE HEAT PUMP

5TWX6048A1

16 Single-Stage Heat Pump with WeatherGuard Top · source records, page 2

54 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity44,000–46,500BTU/h

Each efficiency range summarizes published EPA records for 5TWX6048A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 54 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–1654 / 54
EER2 · BTU/Wh11.69–1254 / 54
HSPF2 · BTU/Wh7.8–8.154 / 54
Cooling capacity · BTU/h44,000–46,50054 / 54
Heating capacity at 47°F / 8.3°C · BTU/h42,000–44,00054 / 54
Heating capacity at 17°F / −8.3°C · BTU/h28,400–29,00054 / 54
Heating capacity at 5°F / −15°C · BTU/h21,800–22,40054 / 54
COP at 5°F / −15°C2.14–2.2854 / 54
Equipment / loop typeHP - Split System54 / 54
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)54 / 54
Compressor stagingSingle stage54 / 54
Connected capabilityNo54 / 54

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5TXCD010AS3+TSTAT+ furnace: L8V1C100U5VSBAHRI reference: 21811102615.207.80220002.18EPA 4575775
5PX*D010AS3+TSTAT+ furnace: S8X1D120M5PTCAHRI reference: 21811092715.208.10220002.19EPA 4575779
5PX*D010AS3+TSTAT+ furnace: S8X1D120M5PSCAHRI reference: 21811092615.208.10220002.19EPA 4575780
5PX*D010AS3+TSTAT+ furnace: S8V2D120M5PDBAHRI reference: 21811092315.208.00220002.18EPA 4575781
5PX*D010AS3+TSTAT+ furnace: S9X1D120U5PSBAHRI reference: 21811092215.208.10220002.17EPA 4575782
5PX*D010AS3+TSTAT+ furnace: S9V2C080U5VSBAHRI reference: 21811091915.208.10220002.16EPA 4575783
5PX*D010AS3+TSTAT+ furnace: S8X2D120M5PTCAHRI reference: 21811091815.208.10220002.19EPA 4575784
5PX*D010AS3+TSTAT+ furnace: S8X2D120M5PSCAHRI reference: 21811091715.208.10220002.19EPA 4575785
5TEMCD05AV41+TDR+TSTATAHRI reference: 21815943015.208.10218002.19EPA 4576547
5TEM6D07AV51+TDR+TSTATAHRI reference: 21815942915.208.10218002.26EPA 4576548
5TEM6D06AV41+TDR+TSTATAHRI reference: 21815942815.208.10218002.27EPA 4576549
5PX*D010AS3+TSTAT+ furnace: S9X2D120U5PSBAHRI reference: 21815942415.208.10220002.17EPA 4576550
5PX*D010AS3+TSTAT+ furnace: S8V2D120M5PCBAHRI reference: 21815942315.208.00220002.18EPA 4576551
5PX*D010AS3+TSTAT+ furnace: S9V2C100U5VSBAHRI reference: 21839639515.208.10224002.15EPA 4599158
5PX*D010AS3+TSTAT+ furnace: S8X1C100M5PTCAHRI reference: 21839639415.208.00220002.15EPA 4599159
5PX*D010AS3+TSTAT+ furnace: L8V1C100U5VSBAHRI reference: 21839639315.208.00220002.17EPA 4599160
5PX*D010AS3+TSTAT+ furnace: S8X1C100M5PSCAHRI reference: 21839638515.208.00220002.15EPA 4599164
5PX*D010AS3+TSTAT+ furnace: S8X2C100M5PSCAHRI reference: 21839638315.208.00220002.15EPA 4599165
5PX*C009AS3+TSTAT+ furnace: S9X2C100U5PSBAHRI reference: 21839638115.208.10224002.15EPA 4599166
5TXCD010AS3+TSTAT+ furnace: *UHMC100CCV4AHRI reference: 21839630815.208.10224002.14EPA 4599182

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →