Trane / AIR-SOURCE HEAT PUMP

5TWX6036A1

16 Single-Stage Heat Pump with WeatherGuard Top · source records, page 6

374 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity32,000–35,400BTU/h

Each efficiency range summarizes published EPA records for 5TWX6036A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 374 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5374 / 374
EER2 · BTU/Wh11.2–12374 / 374
HSPF2 · BTU/Wh7.8–8.1374 / 374
Cooling capacity · BTU/h32,000–35,400374 / 374
Heating capacity at 47°F / 8.3°C · BTU/h29,800–32,400374 / 374
Heating capacity at 17°F / −8.3°C · BTU/h21,000–22,200374 / 374
Heating capacity at 5°F / −15°C · BTU/h16,900–17,700374 / 374
COP at 5°F / −15°C2.22–2.48374 / 374
Equipment / loop typeHP - Split System374 / 374
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)374 / 374
Compressor stagingSingle stage374 / 374
Connected capabilityNo374 / 374

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5PX*C009AS3+TSTAT+ furnace: S9V2C100U4VSBAHRI reference: 21811037116.008.10169002.39EPA 4575431
5PX*C007AS3+TSTAT+ furnace: S8X2C100M5PSCAHRI reference: 21811037016.008.10174002.36EPA 4575432
5PX*C007AS3+TSTAT+ furnace: L8V1C100U5VSBAHRI reference: 21811036916.008.10172002.38EPA 4575433
5PX*C007AS3+TSTAT+ furnace: S9V2C080U5VSBAHRI reference: 21811036816.008.10173002.37EPA 4575434
5PX*C007AS3+TSTAT+ furnace: S9X1C080U5PSBAHRI reference: 21811036716.008.10173002.36EPA 4575435
5PX*C007AS3+TSTAT+ furnace: S9X2C080U5PSBAHRI reference: 21811036516.008.10173002.36EPA 4575437
5PX*C007AS3+TSTAT+P0V0C000M50SDAHRI reference: 21811036316.008.10171002.42EPA 4575439
5PX*C007AS3+TSTAT+ furnace: S8X1C080M5PSCAHRI reference: 21811036216.008.10174002.37EPA 4575440
5PX*C007AS3+TSTAT+ furnace: S8X1C080M5PTCAHRI reference: 21811036116.008.10174002.37EPA 4575441
5PX*C007AS3+TSTAT+ furnace: S8X1C100M5PSCAHRI reference: 21811036016.008.10174002.36EPA 4575442
5PX*C007AS3+TSTAT+ furnace: S8X2C080M5PSCAHRI reference: 21811035916.008.10174002.37EPA 4575443
5PX*C007AS3+TSTAT+ furnace: *UHMC100CCV4AHRI reference: 21811035816.008.10170002.38EPA 4575444
5PX*C007AS3+TSTAT+ furnace: S8X2C100M5PTCAHRI reference: 21811035716.008.10174002.36EPA 4575445
5PX*BD06AS3+TSTAT+P0V0B000M40SDAHRI reference: 21811033416.008.10171002.39EPA 4575466
5PX*B006AS3+TSTAT+P0V0B000M40SDAHRI reference: 21811026916.008.10171002.40EPA 4575507
5TXCD010AS3+TSTAT+ furnace: S8V2D120M5PCBAHRI reference: 21815938316.008.10172002.38EPA 4576566
5TXCC009AS3+TSTAT+ furnace: S8X2C100M5PTCAHRI reference: 21815938216.008.10173002.37EPA 4576567
5TXCC007AS3+TSTAT+ furnace: S9V2C080U5VSBAHRI reference: 21815938116.008.10171002.37EPA 4576568
5PX*DD10AS3+TSTAT+ furnace: S8X2D120M5PSCAHRI reference: 21815937416.008.10173002.35EPA 4576574
5PX*CD09AS3+TSTAT+ furnace: S9V2C100D5VSBAHRI reference: 21815937216.008.10170002.32EPA 4576576

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.