Trane / AIR-SOURCE HEAT PUMP

5TWX6036A1

16 Single-Stage Heat Pump with WeatherGuard Top · source records, page 2

374 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity32,000–35,400BTU/h

Each efficiency range summarizes published EPA records for 5TWX6036A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 374 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5374 / 374
EER2 · BTU/Wh11.2–12374 / 374
HSPF2 · BTU/Wh7.8–8.1374 / 374
Cooling capacity · BTU/h32,000–35,400374 / 374
Heating capacity at 47°F / 8.3°C · BTU/h29,800–32,400374 / 374
Heating capacity at 17°F / −8.3°C · BTU/h21,000–22,200374 / 374
Heating capacity at 5°F / −15°C · BTU/h16,900–17,700374 / 374
COP at 5°F / −15°C2.22–2.48374 / 374
Equipment / loop typeHP - Split System374 / 374
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)374 / 374
Compressor stagingSingle stage374 / 374
Connected capabilityNo374 / 374

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5TXCC009AS3+TSTAT+ furnace: S8X2C080M5PTCAHRI reference: 21811057616.008.10172002.37EPA 4575255
5TXCC009AS3+TSTAT+ furnace: S9V2C100U5VSBAHRI reference: 21811057516.008.10169002.39EPA 4575256
5TXCC009AS3+TSTAT+ furnace: S8V2C100M5PDBAHRI reference: 21811057416.008.10172002.39EPA 4575257
5TXCC009AS3+TSTAT+ furnace: S8V2C100M5PCBAHRI reference: 21811057316.008.10172002.39EPA 4575258
5TXCC009AS3+TSTAT+P0V0C000M50SDAHRI reference: 21811057216.008.10169002.42EPA 4575259
5TXCC009AS3+TSTAT+ furnace: L8V1C100U5VSBAHRI reference: 21811057116.008.10170002.41EPA 4575260
5TXCC009AS3+TSTAT+ furnace: *UHMC100CCV4AHRI reference: 21811057016.008.10169002.40EPA 4575261
5TXCC009AS3+TSTAT+ furnace: S9X1C080U5PSBAHRI reference: 21811056916.008.10172002.38EPA 4575262
5TXCC009AS3+TSTAT+ furnace: S9X2C080U5PSBAHRI reference: 21811056716.008.10172002.38EPA 4575264
5TXCC009AS3+TSTAT+ furnace: S9V2C100U4VSBAHRI reference: 21811056516.008.10169002.39EPA 4575266
5TXCC009AS3+TSTAT+ furnace: S9V2C080U5VSBAHRI reference: 21811056416.008.10172002.38EPA 4575267
5TXCC009AS3+TSTAT+ furnace: S8X1C080M5PSCAHRI reference: 21811056316.008.10172002.37EPA 4575268
5TXCC009AS3+TSTAT+ furnace: S8X2C100M5PSCAHRI reference: 21811056216.008.10173002.37EPA 4575269
5TXCC007AS3+TSTAT+ furnace: S9X1C080U5PSBAHRI reference: 21811056116.008.10173002.36EPA 4575270
5TXCC007AS3+TSTAT+ furnace: S9X2C080U5PSBAHRI reference: 21811055916.008.10173002.36EPA 4575272
5TXCC007AS3+TSTAT+P0V0C000M50SDAHRI reference: 21811055716.008.10171002.41EPA 4575274
5TXCC007AS3+TSTAT+ furnace: *UHMC100CCV4AHRI reference: 21811054816.008.10170002.38EPA 4575283
5TXCB006AS3+TSTAT+P0V0B000M40SDAHRI reference: 21811052216.008.00171002.40EPA 4575307
5TEMCD06AV41+TDR+TSTATAHRI reference: 21811046616.008.10169002.48EPA 4575349
5TEMCD05AV41+TDR+TSTATAHRI reference: 21811046516.008.10170002.45EPA 4575350

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →