Trane / AIR-SOURCE HEAT PUMP

5TWX6036A1

16 Single-Stage Heat Pump with WeatherGuard Top · source records, page 13

374 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity32,000–35,400BTU/h

Each efficiency range summarizes published EPA records for 5TWX6036A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 374 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5374 / 374
EER2 · BTU/Wh11.2–12374 / 374
HSPF2 · BTU/Wh7.8–8.1374 / 374
Cooling capacity · BTU/h32,000–35,400374 / 374
Heating capacity at 47°F / 8.3°C · BTU/h29,800–32,400374 / 374
Heating capacity at 17°F / −8.3°C · BTU/h21,000–22,200374 / 374
Heating capacity at 5°F / −15°C · BTU/h16,900–17,700374 / 374
COP at 5°F / −15°C2.22–2.48374 / 374
Equipment / loop typeHP - Split System374 / 374
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)374 / 374
Compressor stagingSingle stage374 / 374
Connected capabilityNo374 / 374

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5PX*CD05AS3+TSTAT+ furnace: S8X1C080M5PTCAHRI reference: 21811039615.208.00174002.22EPA 4575413
5PX*CD05AS3+TSTAT+ furnace: S8X2C080M5PTCAHRI reference: 21811039315.208.00174002.22EPA 4575414
5PX*C009AS3+TSTAT+ furnace: S9X2C100U5PSBAHRI reference: 21811037515.208.10170002.39EPA 4575427
5PX*C009AS3+TSTAT+ furnace: S9X1C100U5PSBAHRI reference: 21811037315.208.10170002.39EPA 4575429
5PX*C007AS3+TSTAT+ furnace: S9X1C100U5PSBAHRI reference: 21811036615.208.10171002.37EPA 4575436
5PX*C007AS3+TSTAT+ furnace: S9X2C100U5PSBAHRI reference: 21811036415.208.10171002.37EPA 4575438
5PX*C005AS3+TSTAT+ furnace: S8V2C100M5PCBAHRI reference: 21811035615.208.10172002.32EPA 4575446
5PX*C005AS3+TSTAT+ furnace: S8V2C100M5PDBAHRI reference: 21811035515.208.10172002.32EPA 4575447
5PX*C005AS3+TSTAT+ furnace: S8X1C080M5PSCAHRI reference: 21811035415.208.10174002.31EPA 4575448
5PX*C005AS3+TSTAT+ furnace: S8X1C080M5PTCAHRI reference: 21811035315.208.10174002.31EPA 4575449
5PX*C005AS3+TSTAT+ furnace: S8X1C100M5PSCAHRI reference: 21811035215.208.10174002.30EPA 4575450
5PX*C005AS3+TSTAT+ furnace: S8X1C100M5PTCAHRI reference: 21811035115.208.10174002.30EPA 4575451
5PX*C005AS3+TSTAT+ furnace: S8X2C080M5PSCAHRI reference: 21811035015.208.10174002.31EPA 4575452
5PX*C005AS3+TSTAT+ furnace: S8X2C080M5PTCAHRI reference: 21811034915.208.10174002.31EPA 4575453
5PX*C005AS3+TSTAT+ furnace: *UHMC100CCV4AHRI reference: 21811034815.208.10170002.33EPA 4575454
5PX*C005AS3+TSTAT+ furnace: L8V1C100U5VSBAHRI reference: 21811034715.208.10171002.33EPA 4575455
5PX*C005AS3+TSTAT+P0V0C000M50SDAHRI reference: 21811034615.208.10169002.35EPA 4575456
5PX*C005AS3+TSTAT+ furnace: S8X2C100M5PTCAHRI reference: 21811034315.208.10174002.30EPA 4575457
5PX*C005AS3+TSTAT+ furnace: S9V2C100U5VSBAHRI reference: 21811034215.208.10170002.32EPA 4575458
5PX*C005AS3+TSTAT+ furnace: S9X2C100U5PSBAHRI reference: 21811034115.208.10171002.32EPA 4575459

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →