Trane / AIR-SOURCE HEAT PUMP

5TWX6030A1

16 Single-Stage Heat Pump with WeatherGuard Top · source records, page 7

139 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity27,200–29,600BTU/h

Each efficiency range summarizes published EPA records for 5TWX6030A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 139 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16139 / 139
EER2 · BTU/Wh11.7–12139 / 139
HSPF2 · BTU/Wh7.8–8.1139 / 139
Cooling capacity · BTU/h27,200–29,600139 / 139
Heating capacity at 47°F / 8.3°C · BTU/h24,800–26,800139 / 139
Heating capacity at 17°F / −8.3°C · BTU/h16,800–17,700139 / 139
Heating capacity at 5°F / −15°C · BTU/h13,100–13,800139 / 139
COP at 5°F / −15°C2.12–2.28139 / 139
Equipment / loop typeHP - Split System139 / 139
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)139 / 139
Compressor stagingSingle stage139 / 139
Connected capabilityNo139 / 139

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5PX*CD07AS3+TSTAT+ furnace: S9V2C100D4VSBAHRI reference: 21839605415.208.00136002.14EPA 4599280
5PX*CD07AS3+TSTAT+ furnace: S8X1C080M5PSCAHRI reference: 21839605315.207.80136002.13EPA 4599281
5PX*C007AS3+TSTAT+ furnace: S8V2C080M5PCBAHRI reference: 21839604815.208.00135002.17EPA 4599282
5PX*C007AS3+TSTAT+ furnace: S8X2C080M5PSCAHRI reference: 21839604715.208.00135002.18EPA 4599283
5PX*C007AS3+TSTAT+ furnace: S8X1C080M5PSCAHRI reference: 21839604615.208.00135002.18EPA 4599284
5PX*C007AS3+TSTAT+ furnace: S8V2C100M5PDBAHRI reference: 21839604515.208.10136002.18EPA 4599285
5PX*C007AS3+TSTAT+ furnace: S8X2C080M5PTCAHRI reference: 21839604415.208.00135002.18EPA 4599286
5PX*B006AS3+TSTAT+ furnace: S9X2B080U4PSBAHRI reference: 21839602415.208.00136002.17EPA 4599287
5PX*B006AS3+TSTAT+ furnace: S9X1B080U4PSBAHRI reference: 21839602315.208.00136002.17EPA 4599288
5PX*B006AS3+TSTAT+ furnace: S9V2B060U4VSBAHRI reference: 21839602215.208.10136002.16EPA 4599289
5PX*B006AS3+TSTAT+ furnace: S8X2B080M4PTCAHRI reference: 21839602115.208.00135002.16EPA 4599290
5PX*B006AS3+TSTAT+ furnace: S8X2B080M4PSCAHRI reference: 21839602015.208.00135002.16EPA 4599291
5PX*B006AS3+TSTAT+ furnace: S8X2B060M4PTCAHRI reference: 21839601915.208.00135002.18EPA 4599292
5PX*B006AS3+TSTAT+ furnace: S8X2B060M4PSCAHRI reference: 21839601815.208.00135002.18EPA 4599293
5PX*B006AS3+TSTAT+ furnace: S8X1B080M4PTCAHRI reference: 21839601515.208.00135002.16EPA 4599294
5PX*B006AS3+TSTAT+ furnace: S8X1B080M4PSCAHRI reference: 21839601415.208.00135002.16EPA 4599295
5PX*B006AS3+TSTAT+ furnace: S8X1B060M4PTCAHRI reference: 21839601315.208.00135002.18EPA 4599296
5PX*B006AS3+TSTAT+ furnace: S8X1B060M4PSCAHRI reference: 21839601215.208.00135002.18EPA 4599297
5PX*B006AS3+TSTAT+ furnace: *UHMB060CCV3AHRI reference: 21839600815.208.00135002.17EPA 4599299

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →