Trane / AIR-SOURCE HEAT PUMP

5TWX5036A1

15 Single-Stage Heat Pump with WeatherGuard Top · source records, page 7

444 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity31,800–35,000BTU/h

Each efficiency range summarizes published EPA records for 5TWX5036A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 444 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5444 / 444
EER2 · BTU/Wh11.7–12444 / 444
HSPF2 · BTU/Wh7.8–8.5444 / 444
Cooling capacity · BTU/h31,800–35,000444 / 444
Heating capacity at 47°F / 8.3°C · BTU/h29,800–32,600444 / 444
Heating capacity at 17°F / −8.3°C · BTU/h20,800–22,200444 / 444
Heating capacity at 5°F / −15°C · BTU/h16,600–17,700444 / 444
COP at 5°F / −15°C2.1–2.4444 / 444
Equipment / loop typeHP - Split System444 / 444
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)444 / 444
Compressor stagingSingle stage444 / 444
Connected capabilityNo444 / 444

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5PX*CD09AS3+TSTAT+ furnace: S8X2C080M5PTCAHRI reference: 21568706016.008.10174002.20EPA 3651904
5PX*CD09AS3+TSTAT+ furnace: S8X2C080M5PSCAHRI reference: 21568706116.008.10174002.20EPA 3651905
5PX*CD09AS3+TSTAT+ furnace: S8X1C100M5PSCAHRI reference: 21568706316.008.10173002.20EPA 3651907
5PX*CD09AS3+TSTAT+ furnace: S8X1C080M5PTCAHRI reference: 21568706416.008.10174002.20EPA 3651909
5PX*CD09AS3+TSTAT+ furnace: S8X1C080M5PSCAHRI reference: 21568706516.008.10174002.20EPA 3651910
5PX*CD09AS3+TSTAT+ furnace: S8V2C100M5PDBAHRI reference: 21568706616.008.10174002.20EPA 3651911
5PX*CD09AS3+TSTAT+ furnace: S8V2C100M5PCBAHRI reference: 21568706716.008.10174002.20EPA 3651912
5PX*CD09AS3+TSTAT+ furnace: S8V2C080M5PDBAHRI reference: 21568706816.008.10174002.20EPA 3651913
5PX*CD09AS3+TSTAT+ furnace: S8V2C080M5PCBAHRI reference: 21568706916.008.10174002.20EPA 3651914
5PX*CD09AS3+TSTAT+ furnace: S9V2C100D5PSCAHRI reference: 21568707016.008.10175002.20EPA 3651915
5PX*CD09AS3+TSTAT+ furnace: S8X1C100M5PTCAHRI reference: 21568707116.008.10173002.20EPA 3651916
5PX*D008AS3+TSTAT+ furnace: *UHMD120CCV5AHRI reference: 21568707216.008.10173002.30EPA 3651917
5PX*D008AS3+TSTAT+ furnace: S8V2D120M5PCBAHRI reference: 21568707316.008.10176002.30EPA 3651918
5PX*D008AS3+TSTAT+ furnace: S8V2D120M5PDBAHRI reference: 21568707416.008.10176002.30EPA 3651919
5PX*D008AS3+TSTAT+ furnace: S8X1D120M5PSCAHRI reference: 21568707516.008.10174002.30EPA 3651920
5PX*D008AS3+TSTAT+ furnace: S8X1D120M5PTCAHRI reference: 21568707616.008.10174002.30EPA 3651921
5PX*D008AS3+TSTAT+ furnace: S8X2D120M5PSCAHRI reference: 21568707716.008.10174002.30EPA 3651922
5PX*D008AS3+TSTAT+ furnace: S8X2D120M5PTCAHRI reference: 21568707816.008.10174002.30EPA 3651923
5PX*D008AS3+TSTAT+ furnace: S9V2D120U5VSBAHRI reference: 21568707916.008.50174002.30EPA 3651924
5PX*D008AS3+TSTAT+ furnace: S9V2D120U5PSCAHRI reference: 21568708316.008.50174002.30EPA 3651927

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →