Trane / AIR-SOURCE HEAT PUMP

5TWX5036A1

15 Single-Stage Heat Pump with WeatherGuard Top · source records, page 16

444 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity31,800–35,000BTU/h

Each efficiency range summarizes published EPA records for 5TWX5036A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 444 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5444 / 444
EER2 · BTU/Wh11.7–12444 / 444
HSPF2 · BTU/Wh7.8–8.5444 / 444
Cooling capacity · BTU/h31,800–35,000444 / 444
Heating capacity at 47°F / 8.3°C · BTU/h29,800–32,600444 / 444
Heating capacity at 17°F / −8.3°C · BTU/h20,800–22,200444 / 444
Heating capacity at 5°F / −15°C · BTU/h16,600–17,700444 / 444
COP at 5°F / −15°C2.1–2.4444 / 444
Equipment / loop typeHP - Split System444 / 444
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)444 / 444
Compressor stagingSingle stage444 / 444
Connected capabilityNo444 / 444

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5PX*DD10AS3+TSTAT+ furnace: S9X2D120D5PSBAHRI reference: 21568710515.508.10175002.30EPA 3651754
5PX*C009AS3+TSTAT+ furnace: S9X1C100U5PSBAHRI reference: 21568699415.508.10174002.30EPA 3651771
5PX*C009AS3+TSTAT+ furnace: L9X1C100U5VSAAHRI reference: 21568699515.508.10175002.20EPA 3651772
5PX*C009AS3+TSTAT+ furnace: S9X2C100U5PSBAHRI reference: 21568699715.508.10174002.30EPA 3651774
5PX*CD07AS3+TSTAT+ furnace: *DHMC100CCV4AHRI reference: 21568705115.508.10175002.20EPA 3651896
5PX*CD09AS3+TSTAT+ furnace: S9X2C100D5PSBAHRI reference: 21568705515.508.10172002.20EPA 3651899
5PX*CD09AS3+TSTAT+ furnace: S9X1C100D5PSBAHRI reference: 21568705615.508.10172002.20EPA 3651900
5PX*D008AS3+TSTAT+ furnace: S9X1D120U5PSBAHRI reference: 21568708015.508.10170002.30EPA 3651925
5PX*D008AS3+TSTAT+ furnace: S9X2D120U5PSBAHRI reference: 21568708115.508.10170002.30EPA 3651926
5TXCD008AS3+TSTAT+ furnace: S9X1D120U5PSBAHRI reference: 21568718415.508.10170002.30EPA 3651941
5TXCD008AS3+TSTAT+ furnace: S9X2D120U5PSBAHRI reference: 21568718515.508.10170002.30EPA 3651952
5TXCC009AS3+TSTAT+ furnace: S9X1C100U5PSBAHRI reference: 21568716115.508.10174002.30EPA 3651997
5TXCC009AS3+TSTAT+ furnace: S9X2C100U5PSBAHRI reference: 21568717315.508.10174002.30EPA 3652009
5TXCC009AS3+TSTAT+ furnace: L9X1C100U5VSAAHRI reference: 21568717615.508.10175002.20EPA 3652012
5PX*B006AS3+TSTAT+ furnace: S9V2B060U4VSBAHRI reference: 21583166615.508.10174002.30EPA 3737629
5PX*BD06AS3+TSTAT+ furnace: S9V2B040D3VSBAHRI reference: 21583166815.508.10175002.20EPA 3737630
5PX*C005AS3+TSTAT+ furnace: S9V2C080U5VSBAHRI reference: 21583166915.508.10174002.20EPA 3737631
5PX*C005AS3+TSTAT+ furnace: S9V2C100U5VSBAHRI reference: 21583167015.508.10175002.20EPA 3737632
5TXCC005AS3+TSTAT+ furnace: S9V2C100U5VSBAHRI reference: 21583168115.508.10175002.20EPA 3737641
5TXCC005AS3+TSTAT+ furnace: S9V2C080U5VSBAHRI reference: 21583168215.508.10174002.20EPA 3737644

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →