SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity26,400–29,000BTU/h

Each efficiency range summarizes published EPA records for 5TWX5030A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 125 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16125 / 125
EER2 · BTU/Wh11.7–12125 / 125
HSPF2 · BTU/Wh7.8–8.1125 / 125
Cooling capacity · BTU/h26,400–29,000125 / 125
Heating capacity at 47°F / 8.3°C · BTU/h24,200–26,400125 / 125
Heating capacity at 17°F / −8.3°C · BTU/h16,300–17,700125 / 125
Heating capacity at 5°F / −15°C · BTU/h12,700–13,800125 / 125
COP at 5°F / −15°C2–2.2125 / 125
Equipment / loop typeHP - Split System125 / 125
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)125 / 125
Compressor stagingSingle stage125 / 125
Connected capabilityNo125 / 125

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5TXCC007AS3+TSTAT+ furnace: S8X2C080M5PTCAHRI reference: 21418230715.508.10135002.10EPA 3424301
5TXCC007AS3+TSTAT+ furnace: S8X1C080M5PTCAHRI reference: 21418230315.508.10135002.10EPA 3424302
5TXCC007AS3+TSTAT+ furnace: S9V2C080U5PSBAHRI reference: 21418230915.508.10135002.10EPA 3424303
5TXCC007AS3+TSTAT+ furnace: S9V2C080U5PSCAHRI reference: 21418231115.508.10135002.10EPA 3424304
5TXCC007AS3+TSTAT+ furnace: S9V2C100U4VSAAHRI reference: 21418231315.508.10132002.10EPA 3424305
5TXCC007AS3+TSTAT+ furnace: S9V2C100U4VSBAHRI reference: 21418231515.508.10135002.10EPA 3424307
5TXCC007AS3+TSTAT+ furnace: S9V2C100U5PSCAHRI reference: 21418231915.508.10135002.10EPA 3424308
5TXCC007AS3+TSTAT+ furnace: S9X2C080U5PSBAHRI reference: 21418232515.508.10134002.10EPA 3424310
5TXCB006AS3+TSTAT+ furnace: S8V2A040M3PCBAHRI reference: 21418225815.507.80128002.00EPA 3549660
5TXCB006AS3+TSTAT+ furnace: S8V2A040M3PDBAHRI reference: 21418226215.507.80128002.00EPA 3549661
5TXCC007AS3+TSTAT+ furnace: S8V2C080M5PCBAHRI reference: 21418228715.507.80131002.10EPA 3549663
5TXCC007AS3+TSTAT+ furnace: S8V2C080M5PDBAHRI reference: 21418229115.507.80131002.10EPA 3549664
5PX*C007AS3+TSTAT+ furnace: S8X2C080M5PTCAHRI reference: 21568664415.508.00134002.10EPA 3651221
5PX*C007AS3+TSTAT+ furnace: S8X2C080M5PSCAHRI reference: 21568664515.508.00134002.10EPA 3651223
5PX*C007AS3+TSTAT+ furnace: S8X1C080M5PTCAHRI reference: 21568664615.508.00134002.10EPA 3651224
5PX*C007AS3+TSTAT+ furnace: S8X1C080M5PSCAHRI reference: 21568664715.508.00134002.10EPA 3651225
5PX*CD07AS3+TSTAT+ furnace: S8V2C080M5PCBAHRI reference: 21568667015.508.00136002.10EPA 3651231
5PX*CD07AS3+TSTAT+ furnace: S8V2C080M5PDBAHRI reference: 21568667115.508.00136002.10EPA 3651232
5PX*CD07AS3+TSTAT+ furnace: S8V2C100M5PCBAHRI reference: 21568667215.508.00137002.00EPA 3651233
5PX*CD07AS3+TSTAT+ furnace: S8V2C100M5PDBAHRI reference: 21568667915.508.00137002.00EPA 3651240

Sources and documentation