Trane / AIR-SOURCE HEAT PUMP

5TWX5030A1

15 Single-Stage Heat Pump with WeatherGuard Top

125 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity26,400–29,000BTU/h

Each efficiency range summarizes published EPA records for 5TWX5030A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 125 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16125 / 125
EER2 · BTU/Wh11.7–12125 / 125
HSPF2 · BTU/Wh7.8–8.1125 / 125
Cooling capacity · BTU/h26,400–29,000125 / 125
Heating capacity at 47°F / 8.3°C · BTU/h24,200–26,400125 / 125
Heating capacity at 17°F / −8.3°C · BTU/h16,300–17,700125 / 125
Heating capacity at 5°F / −15°C · BTU/h12,700–13,800125 / 125
COP at 5°F / −15°C2–2.2125 / 125
Equipment / loop typeHP - Split System125 / 125
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)125 / 125
Compressor stagingSingle stage125 / 125
Connected capabilityNo125 / 125

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5TXCB006AS3+TSTAT+ furnace: S8X1A040M3PTCAHRI reference: 21418218016.008.10129002.00EPA 3423831 →
5TXCB006AS3+TSTAT+ furnace: S8X2A040M3PSCAHRI reference: 21418219116.008.10129002.00EPA 3423834 →
5TXCB006AS3+TSTAT+ furnace: S8X2A040M3PTCAHRI reference: 21418219316.008.10129002.00EPA 3423835 →
5TXCB006AS3+TSTAT+ furnace: S8X1A040M3PSCAHRI reference: 21418228016.008.10129002.00EPA 3424299 →
5PX*B006AS3+TSTAT+ furnace: S9X1B080U4PSBAHRI reference: 21568654816.008.00137002.10EPA 3651164 →
5PX*B006AS3+TSTAT+ furnace: S9X2B080U4PSBAHRI reference: 21568655116.008.00137002.10EPA 3651165 →
5PX*BD06AS3+TSTAT+P0V0B000M40SDAHRI reference: 21568659816.008.00136002.10EPA 3651166 →
5PX*C007AS3+TSTAT+ furnace: S9X2C080U5PSBAHRI reference: 21568663916.008.00133002.10EPA 3651217 →
5PX*C007AS3+TSTAT+ furnace: S9X1C080U5PSBAHRI reference: 21568664016.008.00133002.10EPA 3651218 →
5PX*C007AS3+TSTAT+ furnace: S9V2C100U5PSCAHRI reference: 21568664116.008.00134002.10EPA 3651219 →
5PX*C007AS3+TSTAT+ furnace: S8V2C100M5PCBAHRI reference: 21568664216.008.10136002.10EPA 3651220 →
5PX*C007AS3+TSTAT+ furnace: S9V2C080U5PSCAHRI reference: 21568664316.008.00135002.10EPA 3651222 →
5PX*C007AS3+TSTAT+ furnace: S8V2C100M5PDBAHRI reference: 21568664816.008.10136002.10EPA 3651226 →
5PX*C007AS3+TSTAT+ furnace: S9V2C100U4VSBAHRI reference: 21568664916.008.00134002.10EPA 3651227 →
5PX*C007AS3+TSTAT+ furnace: S8V2C080M5PDBAHRI reference: 21568665016.008.00135002.10EPA 3651228 →
5PX*C007AS3+TSTAT+ furnace: S8V2C080M5PCBAHRI reference: 21568665116.008.00135002.10EPA 3651229 →
5PX*C007AS3+TSTAT+ furnace: *UHMC100CCV4AHRI reference: 21568665216.008.00134002.10EPA 3651230 →
5PX*CD07AS3+TSTAT+ furnace: S9V2C100D5PSCAHRI reference: 21568667316.008.00135002.10EPA 3651235 →
5PX*CD07AS3+TSTAT+ furnace: S9V2C100D4VSBAHRI reference: 21568667816.008.00135002.10EPA 3651239 →
5PX*D008AS3+TSTAT+ furnace: *UHMD120CCV5AHRI reference: 21568668816.008.00134002.10EPA 3651241 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →