Trane / AIR-SOURCE HEAT PUMP

5TWX5024A1

15 Single-Stage Heat Pump with WeatherGuard Top · source records, page 3

75 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity21,200–25,000BTU/h

Each efficiency range summarizes published EPA records for 5TWX5024A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 75 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.575 / 75
EER2 · BTU/Wh11.7–1275 / 75
HSPF2 · BTU/Wh7.8–8.175 / 75
Cooling capacity · BTU/h21,200–25,00075 / 75
Heating capacity at 47°F / 8.3°C · BTU/h20,600–23,00075 / 75
Heating capacity at 17°F / −8.3°C · BTU/h13,700–15,20075 / 75
Heating capacity at 5°F / −15°C · BTU/h10,600–11,70075 / 75
COP at 5°F / −15°C1.9–2.275 / 75
Equipment / loop typeHP - Split System75 / 75
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)75 / 75
Compressor stagingSingle stage75 / 75
Connected capabilityNo75 / 75

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5TXCB004AS3+TSTAT+ furnace: S8V2B080M4PCBAHRI reference: 21418183915.507.80111002.10EPA 3424746
5TXCB004AS3+TSTAT+ furnace: S8V2B080M4PDAAHRI reference: 21418184115.507.80111002.10EPA 3424747
5TXCB004AS3+TSTAT+ furnace: S8V2B080M4PDBAHRI reference: 21418184315.507.80111002.10EPA 3424748
5TXCB004AS3+TSTAT+ furnace: S9V2B040U3PSBAHRI reference: 21418187315.507.80111002.10EPA 3424750
5TXCB004AS3+TSTAT+ furnace: S9V2B040U3PSCAHRI reference: 21418187515.507.80111002.10EPA 3424751
5TXCB004AS3+TSTAT+ furnace: S9V2B040U3VSAAHRI reference: 21418187715.507.80111002.10EPA 3424752
5TXCB004AS3+TSTAT+ furnace: S9V2B040U3VSBAHRI reference: 21418187915.507.80111002.10EPA 3424753
5TXCB004AS3+TSTAT+ furnace: S9V2B060U3VSAAHRI reference: 21418188115.507.80111002.10EPA 3424755
5TXCB004AS3+TSTAT+ furnace: S9V2B060U3VSBAHRI reference: 21418188415.507.80113002.10EPA 3424756
5TXCB004AS3+TSTAT+ furnace: S9V2B060U4PSBAHRI reference: 21418188615.507.80111002.10EPA 3424757
5TXCB004AS3+TSTAT+ furnace: S9V2B060U4PSCAHRI reference: 21418188815.507.80111002.10EPA 3424758
5TXCB004AS3+TSTAT+ furnace: *UHMB060ACV3AHRI reference: 21418189015.507.80110002.10EPA 3424759
5TXCB004AS3+TSTAT+ furnace: S9V2B080U4PSBAHRI reference: 21418189215.507.80111002.10EPA 3424760
5TXCB004AS3+TSTAT+ furnace: S9V2B080U4VSAAHRI reference: 21418189615.507.80113002.10EPA 3424761
5TXCB004AS3+TSTAT+ furnace: S9X1B040U3PSBAHRI reference: 21418189815.507.80111002.10EPA 3424763
5TXCB004AS3+TSTAT+ furnace: S9X1B060U4PSBAHRI reference: 21418190015.507.80111002.10EPA 3424764
5TXCB004AS3+TSTAT+ furnace: S9X1B080U4PSBAHRI reference: 21418190215.508.10112002.10EPA 3424765
5TXCB004AS3+TSTAT+ furnace: S9X2B040U3PSBAHRI reference: 21418190415.507.80111002.10EPA 3424766
5TXCB004AS3+TSTAT+ furnace: S9X2B060U4PSBAHRI reference: 21418191115.507.80111002.10EPA 3424767
5TXCB004AS3+TSTAT+ furnace: S9X2B080U4PSBAHRI reference: 21418191315.508.10112002.10EPA 3424768

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.