Trane / AIR-SOURCE HEAT PUMP

5TWX5018A1

15 Single-Stage Heat Pump with WeatherGuard Top

6 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity17,800–19,200BTU/h

Each efficiency range summarizes published EPA records for 5TWX5018A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 6 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–166 / 6
EER2 · BTU/Wh11.7–126 / 6
HSPF2 · BTU/Wh7.8–8.16 / 6
Cooling capacity · BTU/h17,800–19,2006 / 6
Heating capacity at 47°F / 8.3°C · BTU/h17,200–18,6006 / 6
Heating capacity at 17°F / −8.3°C · BTU/h11,200–12,2006 / 6
Heating capacity at 5°F / −15°C · BTU/h8,600–9,3006 / 6
COP at 5°F / −15°C1.9–2.16 / 6
Equipment / loop typeHP - Split System6 / 6
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)6 / 6
Compressor stagingSingle stage6 / 6
Connected capabilityNo6 / 6

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5TXCB004AS3+TSTAT+ furnace: L9X1A050U3VSAAHRI reference: 21418165116.007.8086001.90EPA 3423662
5TEMCB03AV31+TDR+TSTATAHRI reference: 21586396116.008.1089002.10EPA 3737764
5TEM6B03AV21+TDR+TSTATAHRI reference: 21418159615.508.1092002.00EPA 3423661
5TEMCB02AV21+TDR+TSTATAHRI reference: 21586396015.508.0089002.10EPA 3737763
5TEM4B02AC21+TDR+TSTATAHRI reference: 21561096315.207.8090002.00EPA 3651455
5TEM6B02AV21+TDR+TSTATAHRI reference: 21561096515.207.8093002.00EPA 3651456

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →