5TWV8X36A1
18 TruComfort Variable Speed Heat Pump · source records, page 4
201 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 5TWV8X36A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 201 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 17.1–18.1 | 201 / 201 |
| EER2 · BTU/Wh | 9.8–11 | 201 / 201 |
| HSPF2 · BTU/Wh | 8.5 | 201 / 201 |
| Cooling capacity · BTU/h | 31,400–33,600 | 201 / 201 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 32,200–34,600 | 201 / 201 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 30,400–32,200 | 201 / 201 |
| Heating capacity at 5°F / −15°C · BTU/h | 24,800–26,000 | 201 / 201 |
| COP at 5°F / −15°C | 1.9–2.2 | 201 / 201 |
| Equipment / loop type | HP - Split System | 201 / 201 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 201 / 201 |
| Compressor staging | Continuously variable | 201 / 201 |
| Connected capability | No | 201 / 201 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
5PX*C005AS3+ furnace: S9V2C100U4VSB+LRPCold climate designationAHRI reference: 215864535 | 18.10 | 8.50 | 25400 | 2.10 | EPA 3715609 → |
5PX*C005AS3+ furnace: S9V2C100U5PSC+LRPCold climate designationAHRI reference: 215864537 | 18.10 | 8.50 | 25400 | 2.10 | EPA 3715611 → |
5PX*C007AS3+ furnace: S8V2C100M5PCBCold climate designationAHRI reference: 215864539 | 18.10 | 8.50 | 25600 | 2.10 | EPA 3715613 → |
5PX*C007AS3+ furnace: S8V2C100M5PDBCold climate designationAHRI reference: 215864541 | 18.10 | 8.50 | 25600 | 2.10 | EPA 3715615 → |
5PX*C007AS3+ furnace: S9V2C080U5PSC+LRPCold climate designationAHRI reference: 215864543 | 18.10 | 8.50 | 25600 | 2.10 | EPA 3715617 → |
5PX*C007AS3+ furnace: S9V2C100U4VSB+LRPCold climate designationAHRI reference: 215864545 | 18.10 | 8.50 | 25400 | 2.10 | EPA 3715619 → |
5PX*C007AS3+ furnace: S8V2C080M5PCBCold climate designationAHRI reference: 215864547 | 18.10 | 8.50 | 25400 | 2.10 | EPA 3715621 → |
5PX*C007AS3+ furnace: *UHMC100CCV4+LRPCold climate designationAHRI reference: 215864549 | 18.10 | 8.50 | 25400 | 2.10 | EPA 3715623 → |
5PX*C007AS3+ furnace: S8V2C080M5PDBCold climate designationAHRI reference: 215864551 | 18.10 | 8.50 | 25400 | 2.10 | EPA 3715625 → |
5PX*C007AS3+ furnace: S9V2C100U5PSC+LRPCold climate designationAHRI reference: 215864553 | 18.10 | 8.50 | 25400 | 2.10 | EPA 3715627 → |
5PX*CD05AS3+ furnace: S9V2C100D4VSB+LRPCold climate designationAHRI reference: 215864555 | 18.10 | 8.50 | 25600 | 2.00 | EPA 3715629 → |
5PX*CD05AS3+ furnace: S8V2C100M5PDBCold climate designationAHRI reference: 215864557 | 18.10 | 8.50 | 25800 | 2.00 | EPA 3715631 → |
5PX*CD05AS3+ furnace: S8V2C100M5PCBCold climate designationAHRI reference: 215864559 | 18.10 | 8.50 | 25800 | 2.00 | EPA 3715633 → |
5PX*CD05AS3+ furnace: S8V2C080M5PDBCold climate designationAHRI reference: 215864561 | 18.10 | 8.50 | 25600 | 2.00 | EPA 3715635 → |
5PX*CD05AS3+ furnace: S8V2C080M5PCBCold climate designationAHRI reference: 215864563 | 18.10 | 8.50 | 25600 | 2.00 | EPA 3715637 → |
5PX*CD05AS3+ furnace: S9V2C100D5PSC+LRPCold climate designationAHRI reference: 215864565 | 18.10 | 8.50 | 25600 | 2.00 | EPA 3715639 → |
5PX*CD05AS3+ furnace: *DHMC100CCV4+LRPCold climate designationAHRI reference: 215864567 | 18.10 | 8.50 | 25800 | 2.00 | EPA 3715641 → |
5TXCB004AS3+ furnace: S9V2B060U3VSB+LRPCold climate designationAHRI reference: 215864569 | 18.10 | 8.50 | 25600 | 2.00 | EPA 3715643 → |
5TXCB004AS3+ furnace: S9V2B040U3VSB+LRPCold climate designationAHRI reference: 215864571 | 18.10 | 8.50 | 25400 | 2.00 | EPA 3715645 → |
5TXCB004AS3+ furnace: S9V2B040U3PSC+LRPCold climate designationAHRI reference: 215864573 | 18.10 | 8.50 | 25600 | 2.00 | EPA 3715647 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →