5TWV8X36A1
18 TruComfort Variable Speed Heat Pump
201 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 5TWV8X36A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 201 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 17.1–18.1 | 201 / 201 |
| EER2 · BTU/Wh | 9.8–11 | 201 / 201 |
| HSPF2 · BTU/Wh | 8.5 | 201 / 201 |
| Cooling capacity · BTU/h | 31,400–33,600 | 201 / 201 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 32,200–34,600 | 201 / 201 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 30,400–32,200 | 201 / 201 |
| Heating capacity at 5°F / −15°C · BTU/h | 24,800–26,000 | 201 / 201 |
| COP at 5°F / −15°C | 1.9–2.2 | 201 / 201 |
| Equipment / loop type | HP - Split System | 201 / 201 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 201 / 201 |
| Compressor staging | Continuously variable | 201 / 201 |
| Connected capability | No | 201 / 201 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
5PX*BD04AS3+ furnace: S8V2A040M3PCBCold climate designationAHRI reference: 215864515 | 18.10 | 8.50 | 25800 | 1.90 | EPA 3715429 → |
5TXCB004AS3+ furnace: S9V2B080U4VSB+LRPCold climate designationAHRI reference: 215864591 | 18.10 | 8.50 | 25600 | 2.00 | EPA 3715432 → |
5TXCB004AS3+ furnace: S9V2B080U4PSC+LRPCold climate designationAHRI reference: 215864593 | 18.10 | 8.50 | 25600 | 2.00 | EPA 3715434 → |
5TXCB006AS3+ furnace: *UHMB060CCV3+LRPCold climate designationAHRI reference: 215864595 | 18.10 | 8.50 | 25800 | 2.10 | EPA 3715436 → |
5TXCB006AS3+ furnace: *UHMB080CCV3+LRPCold climate designationAHRI reference: 215864597 | 18.10 | 8.50 | 25600 | 2.10 | EPA 3715438 → |
5TXCB006AS3+ furnace: S9V2B080U4VSB+LRPCold climate designationAHRI reference: 215864599 | 18.10 | 8.50 | 25600 | 2.10 | EPA 3715440 → |
5TXCB006AS3+ furnace: S9V2B080U4PSC+LRPCold climate designationAHRI reference: 215864601 | 18.10 | 8.50 | 25600 | 2.10 | EPA 3715442 → |
5TXCB006AS3+ furnace: S9V2B060U4PSC+LRPCold climate designationAHRI reference: 215864603 | 18.10 | 8.50 | 25800 | 2.10 | EPA 3715444 → |
5TXCB006AS3+ furnace: S9V2B060U3VSB+LRPCold climate designationAHRI reference: 215864605 | 18.10 | 8.50 | 25800 | 2.10 | EPA 3715446 → |
5TXCB006AS3+ furnace: S9V2B040U3VSB+LRPCold climate designationAHRI reference: 215864607 | 18.10 | 8.50 | 25800 | 2.10 | EPA 3715448 → |
5TXCB006AS3+ furnace: S9V2B040U3PSC+LRPCold climate designationAHRI reference: 215864609 | 18.10 | 8.50 | 25800 | 2.10 | EPA 3715450 → |
5TXCB006AS3+ furnace: S8V2B080M4PDBCold climate designationAHRI reference: 215864611 | 18.10 | 8.50 | 25800 | 2.10 | EPA 3715452 → |
5TXCB006AS3+ furnace: S8V2B080M4PCBCold climate designationAHRI reference: 215864613 | 18.10 | 8.50 | 25800 | 2.10 | EPA 3715454 → |
5TXCB006AS3+ furnace: L8V1A040U3VSB+LRPCold climate designationAHRI reference: 215864615 | 18.10 | 8.50 | 25800 | 2.00 | EPA 3715456 → |
5TXCB006AS3+ furnace: L8V1A060U3VSB+LRPCold climate designationAHRI reference: 215864617 | 18.10 | 8.50 | 25800 | 2.00 | EPA 3715458 → |
5TXCB006AS3+ furnace: L8V1B080U4VSB+LRPCold climate designationAHRI reference: 215864619 | 18.10 | 8.50 | 25800 | 2.10 | EPA 3715460 → |
5TXCB006AS3+ furnace: S8V2A040M3PCBCold climate designationAHRI reference: 215864621 | 18.10 | 8.50 | 25600 | 2.00 | EPA 3715462 → |
5TXCB006AS3+ furnace: S8V2A040M3PDBCold climate designationAHRI reference: 215864623 | 18.10 | 8.50 | 25600 | 2.00 | EPA 3715464 → |
5TXCB006AS3+ furnace: S8V2B060M4PCBCold climate designationAHRI reference: 215864625 | 18.10 | 8.50 | 25600 | 2.10 | EPA 3715466 → |
5TXCB006AS3+ furnace: S8V2B060M4PDBCold climate designationAHRI reference: 215864627 | 18.10 | 8.50 | 25600 | 2.10 | EPA 3715468 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →