5TWV8X24A1
18 TruComfort Variable Speed Heat Pump · source records, page 2
80 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 5TWV8X24A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 80 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 18.1 | 80 / 80 |
| EER2 · BTU/Wh | 11.5 | 80 / 80 |
| HSPF2 · BTU/Wh | 8.5 | 80 / 80 |
| Cooling capacity · BTU/h | 21,400–22,200 | 80 / 80 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 22,800–23,800 | 80 / 80 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 22,400–23,200 | 80 / 80 |
| Heating capacity at 5°F / −15°C · BTU/h | 17,600–18,700 | 80 / 80 |
| COP at 5°F / −15°C | 2.1–2.27 | 80 / 80 |
| Equipment / loop type | HP - Split System | 80 / 80 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 80 / 80 |
| Compressor staging | Continuously variable | 80 / 80 |
| Connected capability | No | 80 / 80 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
5PX*BD06AS3+ furnace: S8V2B080M4PCBCold climate designationAHRI reference: 216571212 | 18.10 | 8.50 | 18600 | 2.20 | EPA 3848799 → |
5PX*BD06AS3+ furnace: S8V2B060M4PDBCold climate designationAHRI reference: 216571214 | 18.10 | 8.50 | 18700 | 2.20 | EPA 3848801 → |
5PX*BD06AS3+ furnace: S8V2B060M4PCBCold climate designationAHRI reference: 216571216 | 18.10 | 8.50 | 18700 | 2.20 | EPA 3848802 → |
5PX*BD06AS3+ furnace: S9V2B080D4PSC+LRPCold climate designationAHRI reference: 216599681 | 18.10 | 8.50 | 18700 | 2.20 | EPA 3957204 → |
5PX*B006AS3+ furnace: S9V2B080U4PSC+LRPCold climate designationAHRI reference: 216599679 | 18.10 | 8.50 | 18700 | 2.20 | EPA 3957206 → |
5PX*B006AS3+ furnace: S9V2B060U3VSB+LRPCold climate designationAHRI reference: 217179509 | 18.10 | 8.50 | 18700 | 2.20 | EPA 4010531 → |
5PX*B006AS3+ furnace: S9V2B040U3VSB+LRPCold climate designationAHRI reference: 217179511 | 18.10 | 8.50 | 18600 | 2.20 | EPA 4010532 → |
5PX*B006AS3+ furnace: S9V2B040U3PSC+LRPCold climate designationAHRI reference: 217179515 | 18.10 | 8.50 | 18600 | 2.20 | EPA 4010536 → |
5PX*B006AS3+P0V0A000M30SD+LRPCold climate designationAHRI reference: 217179513 | 18.10 | 8.50 | 18600 | 2.20 | EPA 4010537 → |
5PX*B006AS3+ furnace: S9V2B080U4VSB+LRPCold climate designationAHRI reference: 217179517 | 18.10 | 8.50 | 18700 | 2.20 | EPA 4010539 → |
5PX*B006AS3+ furnace: S9V2B060U4VSB+LRPCold climate designationAHRI reference: 217179519 | 18.10 | 8.50 | 18700 | 2.20 | EPA 4010541 → |
5PX*B006AS3+ furnace: S9V2B060U4PSC+LRPCold climate designationAHRI reference: 217179521 | 18.10 | 8.50 | 18700 | 2.20 | EPA 4010543 → |
5PX*BD04AS3+ furnace: S9V2B040D3VSB+LRPCold climate designationAHRI reference: 217179523 | 18.10 | 8.50 | 18500 | 2.10 | EPA 4010545 → |
5PX*BD04AS3+ furnace: S9V2B060D3PSC+LRPCold climate designationAHRI reference: 217179525 | 18.10 | 8.50 | 18500 | 2.10 | EPA 4010547 → |
5PX*BD04AS3+ furnace: S9V2B060D3VSB+LRPCold climate designationAHRI reference: 217179527 | 18.10 | 8.50 | 18500 | 2.10 | EPA 4010549 → |
5PX*BD04AS3+ furnace: S9V2B080D4PSC+LRPCold climate designationAHRI reference: 217179529 | 18.10 | 8.50 | 18600 | 2.10 | EPA 4010551 → |
5PX*BD04AS3+ furnace: S9V2B040D3PSC+LRPCold climate designationAHRI reference: 217179531 | 18.10 | 8.50 | 18500 | 2.10 | EPA 4010553 → |
5PX*BD04AS3+ furnace: S8V2B080M4PCBCold climate designationAHRI reference: 217179533 | 18.10 | 8.50 | 18500 | 2.10 | EPA 4010555 → |
5PX*BD04AS3+ furnace: S8V2B060M4PCBCold climate designationAHRI reference: 217179535 | 18.10 | 8.50 | 18500 | 2.20 | EPA 4010557 → |
5PX*BD04AS3+ furnace: S8V2A040M3PCBCold climate designationAHRI reference: 217179537 | 18.10 | 8.50 | 18500 | 2.10 | EPA 4010559 → |