Trane / AIR-SOURCE HEAT PUMP

5TWR7060A1

17 Multi-Speed Heat Pump · source records, page 4

140 published source records · source checked Sep 21, 2026

SEER2 range15.2–17.1BTU/Wh
HSPF2 range8.5–9BTU/Wh
Cooling capacity50,500–53,000BTU/h

Each efficiency range summarizes published EPA records for 5TWR7060A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 140 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17.1140 / 140
EER2 · BTU/Wh10–11.7140 / 140
HSPF2 · BTU/Wh8.5–9140 / 140
Cooling capacity · BTU/h50,500–53,000140 / 140
Heating capacity at 47°F / 8.3°C · BTU/h50,500–52,000140 / 140
Heating capacity at 17°F / −8.3°C · BTU/h33,400–47,500140 / 140
Heating capacity at 5°F / −15°C · BTU/h38,000–39,500140 / 140
COP at 5°F / −15°C2.1–2.22140 / 140
Equipment / loop typeHP - Split System140 / 140
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)140 / 140
Compressor stagingTwo-stage140 / 140
Connected capabilityNo140 / 140

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5TXCD010AS3+ furnace: L9X1C100U5VSACold climate designationAHRI reference: 21676409916.009.00390002.10EPA 4513193 →
5PX*D008AS3+ furnace: L8V1C100U5VSBCold climate designationAHRI reference: 21676404916.009.00390002.10EPA 4513209 →
5PX*DD10AS3+ furnace: S8X2C100M5PSCCold climate designationAHRI reference: 21676488316.009.00385002.10EPA 4513452 →
5PX*DD10AS3+ furnace: S8X1C080M5PTCCold climate designationAHRI reference: 21676488716.009.00385002.10EPA 4513463 →
5PX*DD10AS3+ furnace: S8X2C080M5PTCCold climate designationAHRI reference: 21676488916.009.00385002.10EPA 4513469 →
5PX*DD10AS3+ furnace: S8X1C100M5PTCCold climate designationAHRI reference: 21676487716.009.00385002.10EPA 4513472 →
5PX*DD10AS3+ furnace: S8X2C100M5PTCCold climate designationAHRI reference: 21676489116.009.00385002.10EPA 4513493 →
5PX*DD10AS3+ furnace: S8X2C080M5PSCCold climate designationAHRI reference: 21676488116.009.00385002.10EPA 4513494 →
5TXCD008AS3+ furnace: S8X1D120M5PSCCold climate designationAHRI reference: 21677008016.008.70390002.10EPA 4585363 →
5TXCD008AS3+ furnace: S8X2D120M5PTCCold climate designationAHRI reference: 21677007616.008.70390002.10EPA 4585367 →
5TXCD008AS3+ furnace: S8X2D120M5PSCCold climate designationAHRI reference: 21677007416.008.70390002.10EPA 4585369 →
5TXCD008AS3+ furnace: S8X1D120M5PTCCold climate designationAHRI reference: 21677007216.008.70390002.10EPA 4585371 →
5TXCD010AS3+ furnace: S8V2D120M5PCBCold climate designationAHRI reference: 21676677616.009.00385002.20EPA 4585591 →
5TXCD010AS3+ furnace: S9X1C080U5PSBCold climate designationAHRI reference: 21676677216.008.70385002.20EPA 4585595 →
5TXCD010AS3+ furnace: S9X2C080U5PSBCold climate designationAHRI reference: 21676676616.008.70385002.20EPA 4585601 →
5TXCD010AS3+ furnace: S8V2D120M5PDBCold climate designationAHRI reference: 21676676216.009.00385002.20EPA 4585605 →
5TXCD010AS3+P0V0C000M50SDCold climate designationAHRI reference: 21676676016.009.00385002.20EPA 4585607 →
5TXCD008AS3+P0V0D000M50SDCold climate designationAHRI reference: 21676673416.009.00385002.20EPA 4585629 →
5PX*D010AS3+ furnace: S8V2D120M5PDBCold climate designationAHRI reference: 21676669216.009.00385002.20EPA 4585651 →
5PX*D010AS3+P0V0C000M50SDCold climate designationAHRI reference: 21676668816.009.00385002.20EPA 4585653 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →