Trane / AIR-SOURCE HEAT PUMP

5TWR7048A1

17 Multi-Speed Heat Pump · source records, page 7

231 published source records · source checked Sep 21, 2026

SEER2 range15.2–17.1BTU/Wh
HSPF2 range8.5–9.4BTU/Wh
Cooling capacity43,000–44,500BTU/h

Each efficiency range summarizes published EPA records for 5TWR7048A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 231 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17.1231 / 231
EER2 · BTU/Wh11.2–12.5231 / 231
HSPF2 · BTU/Wh8.5–9.4231 / 231
Cooling capacity · BTU/h43,000–44,500231 / 231
Heating capacity at 47°F / 8.3°C · BTU/h43,500–46,000231 / 231
Heating capacity at 17°F / −8.3°C · BTU/h28,800–41,000231 / 231
Heating capacity at 5°F / −15°C · BTU/h31,800–33,800231 / 231
COP at 5°F / −15°C2.1–2.26231 / 231
Equipment / loop typeHP - Split System231 / 231
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)231 / 231
Compressor stagingTwo-stage231 / 231
Connected capabilityNo231 / 231

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5PX*D008AS3+ furnace: S9X1C080U5PSBCold climate designationAHRI reference: 21676649016.508.70332002.20EPA 3983269
5PX*D008AS3+ furnace: S9V2C080U5VSBAHRI reference: 21676649216.509.00326002.22EPA 3983271
5PX*D008AS3+ furnace: S8V2D120M5PCBAHRI reference: 21676649416.509.00324002.23EPA 3983273
5PX*D010AS3+ furnace: S8V2C080M5PCBAHRI reference: 21676650616.508.70320002.21EPA 3983285
5PX*D010AS3+ furnace: S8V2C100M5PCBAHRI reference: 21676650816.508.70320002.22EPA 3983287
5PX*D010AS3+ furnace: S9V2C080U5VSBAHRI reference: 21676651216.508.70320002.23EPA 3983291
5PX*D010AS3+ furnace: S9V2C100U5VSBCold climate designationAHRI reference: 21676651416.508.70320002.20EPA 3983293
5PX*DD10AS3+P0V0D000M50SDAHRI reference: 21676653416.508.70320002.22EPA 3983344
5TXCC007AS3+P0V0C000M50SDAHRI reference: 21676655616.509.00324002.23EPA 3983358
5TXCC009AS3+ furnace: S8V2C080M5PCBCold climate designationAHRI reference: 21676655816.508.70322002.20EPA 3983360
5TXCC009AS3+ furnace: S9X1C080U5PSBAHRI reference: 21676656616.508.70320002.21EPA 3983364
5TXCC009AS3+ furnace: S9V2C080U5VSBAHRI reference: 21676657016.508.70320002.22EPA 3983368
5TXCC009AS3+ furnace: S8V2C100M5PCBAHRI reference: 21676657216.508.70320002.21EPA 3983370
5TXCD008AS3+ furnace: S9V2C080U5VSBAHRI reference: 21676658016.509.00326002.22EPA 3983374
5TXCD008AS3+ furnace: S9X1C080U5PSBCold climate designationAHRI reference: 21676658416.508.70332002.20EPA 3983378
5TXCD008AS3+ furnace: S8V2D120M5PCBAHRI reference: 21676659216.509.00324002.23EPA 3983420
5TXCD010AS3+ furnace: S9X1C080U5PSBAHRI reference: 21676660416.508.70320002.22EPA 3983428
5TXCD010AS3+ furnace: S9V2C100U5VSBAHRI reference: 21676661016.508.70320002.21EPA 3983432
5TXCD010AS3+ furnace: S9V2C080U5VSBAHRI reference: 21676661216.508.70320002.22EPA 3983434
5TXCD010AS3+ furnace: S8V2C100M5PCBAHRI reference: 21676661616.508.70320002.22EPA 3983438

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →