Trane / AIR-SOURCE HEAT PUMP

5TWR7036A1

17 Multi-Speed Heat Pump · source records, page 15

518 published source records · source checked Sep 21, 2026

SEER2 range15.2–17.1BTU/Wh
HSPF2 range8.2–9.4BTU/Wh
Cooling capacity31,400–34,800BTU/h

Each efficiency range summarizes published EPA records for 5TWR7036A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 518 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17.1518 / 518
EER2 · BTU/Wh11–12.5518 / 518
HSPF2 · BTU/Wh8.2–9.4518 / 518
Cooling capacity · BTU/h31,400–34,800518 / 518
Heating capacity at 47°F / 8.3°C · BTU/h31,400–33,800518 / 518
Heating capacity at 17°F / −8.3°C · BTU/h20,800–29,600518 / 518
Heating capacity at 5°F / −15°C · BTU/h23,600–24,800518 / 518
COP at 5°F / −15°C1.9–2.2518 / 518
Equipment / loop typeHP - Split System518 / 518
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)518 / 518
Compressor stagingTwo-stage518 / 518
Connected capabilityNo518 / 518

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5PX*B006AS3+ furnace: *UHMB060CCV3Cold climate designationAHRI reference: 21676990217.008.70240002.10EPA 3983818
5PX*B006AS3+ furnace: *UHMB080CCV3Cold climate designationAHRI reference: 21676990417.008.70240002.10EPA 3983820
5PX*C009AS3+ furnace: S8X1C100M5PSCCold climate designationAHRI reference: 21676991817.009.00242002.20EPA 3983830
5PX*C009AS3+ furnace: S8X2C100M5PTCCold climate designationAHRI reference: 21676992017.009.00242002.20EPA 3983832
5PX*C009AS3+ furnace: S8X2C100M5PSCCold climate designationAHRI reference: 21676992217.009.00242002.20EPA 3983834
5PX*C009AS3+ furnace: S8X1C100M5PTCCold climate designationAHRI reference: 21676992417.009.00242002.20EPA 3983836
5PX*CD09AS3+ furnace: S8X1C100M5PSCCold climate designationAHRI reference: 21676992817.008.70242002.10EPA 3983840
5PX*CD09AS3+ furnace: S8X1C100M5PTCCold climate designationAHRI reference: 21676993017.008.70242002.10EPA 3983842
5PX*CD09AS3+ furnace: S8X2C100M5PSCCold climate designationAHRI reference: 21676993217.008.70242002.10EPA 3983844
5PX*CD09AS3+ furnace: S8X2C100M5PTCCold climate designationAHRI reference: 21676993417.008.70242002.10EPA 3983846
5TXCC009AS3+ furnace: S8X2C100M5PSCCold climate designationAHRI reference: 21676997417.009.00242002.20EPA 3983882
5TXCC009AS3+ furnace: S8X2C100M5PTCCold climate designationAHRI reference: 21676997617.009.00242002.20EPA 3983884
5TXCC009AS3+ furnace: S8X1C100M5PSCCold climate designationAHRI reference: 21676998617.009.00242002.20EPA 3983894
5TXCC009AS3+ furnace: S8X1C100M5PTCCold climate designationAHRI reference: 21676998817.009.00242002.20EPA 3983896
5TXCD008AS3+ furnace: S8X2D120M5PSCCold climate designationAHRI reference: 21676999617.008.70238002.10EPA 3983904
5TXCD008AS3+ furnace: S8X2D120M5PTCCold climate designationAHRI reference: 21676999817.008.70238002.10EPA 3983907
5TXCD008AS3+ furnace: S8X1D120M5PSCCold climate designationAHRI reference: 21677000017.008.70238002.10EPA 3983908
5TXCD008AS3+ furnace: S8X1D120M5PTCCold climate designationAHRI reference: 21677000217.008.70238002.10EPA 3983909
5PX*C005AS3+ furnace: L9X1C100U5VSACold climate designationAHRI reference: 21676368417.008.70246002.10EPA 4513139
5TXCC007AS3+ furnace: S8V2C080M5PDBCold climate designationAHRI reference: 21676637417.008.70242002.10EPA 4585778

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →